8.3.5 Data (D1 to D7 : 7 words under 6-digit data format)
(D1 to D8 : 8 words under 7-digit data format)
D*
Code
0~9
30H~39H
2EH
20H
8.3.6 Units
U1
U2
8.3.7 Judgment result / Type of data (S1 = 1 word))
S1 Code
Contents
4CH
Short(LO)
47H
Proper(OK)
48H
Exceed(HI)
55H
Unit weight
54H
Total weight
70H
Lower limit value
q
71H
Upper limit value
20H
No judgment/No set of type of data (Pieces and weight)

8.3.8 Status of data

S2
Code
53H
55H
45H
20H
In the case of data (Unit weight, Total value) which is not related to the
measurement condition of Stable/Unstable, "S" "U" are outputted, but it is no
meaning.
- 16 -
VC series bench scales Technical Manual
Data 0 to 9 (Max. 6 digits under 6-digit format)
Decimal point (position is unfixed)
*In the case of an integral number, it can be omitted
and space (SP) can be outputted to the smallest digit
instead.
Space ; Leading zero suppression
(U1,U2 = 2 words) *Based on ASCIIcode
Contents
Symbol
Kilogram
Milligram
(Limit function is set and Quantity data output only)
Type of data
(S2 = 1 word)
Data stable
Data unstable
Erroneous data (All data unreliable except S2 when
「0-err」 、 「u-err」displays)
No specified status
Contents
(Max. 7 digits under 7-digit format)
U1
U2 Contents Symbol
kg
mg
Judgment results
Contents
gram
g
Quantity
(PCS)