Section 6 Function Setting And Calibrate; Enter Function Setting Mode - Vetek VC Series Technical Manual

Counting scales
Table of Contents

Advertisement

Press
shows that currently set at Piece. W display. Press
at Weighing display, and high limit value shows that currently set at UNIT.W
display. Press
In case that only one point (13.Pn. 1) is selected to set, low limit value shows
after press
5.5.3 Comparing ( how limit function work )
Suppose two limits have been set;
When the quantity is under the low value, it is ranked as " LO "
When the quantity is between the low value and the high, it is ranked as " OK "
When the quantity is over the high value, it is ranked as " HI "
Notes
# Such settings as lower limit value >= Higher limit value will be error.
# Comparative judgment condition;
At one point(13.Pn. 1) :
L O : v a l u e < lower limit.
OK: lower limit =< value.
At two point(13.Pn. 2) :
LO: value < lower limit
OK: lower limit =< value =< higher limit
HI : higher limit< value
# We get beep sound in response to comparing result.
The condition is selectable by function set.

SECTION 6 FUNCTION SETTING AND CALIBRATE

6. 1 Enter function setting mode

key until LOW/TOTAL display shows " FSET " . followed by F0 SEL
1) Hold
2) To change setting parameter, press
3) To confirm setting change and forward to the title, press
VC series bench scales Technical Manual
key. Li-LO appears at Weighing display, and low limit value
key. Go back to working area.
key at once go back to working area.
or
key
key. Li-HI appears
key.
- 9 -

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vc-30Vc-60Vc-150V-300V-600

Table of Contents