SECTION 7. CALIBRATION
Select technical parameter CAL mode and select desired setting Linear (linear
calibration) and nonLin (Normal Calibration)
7.1 Normal Calibration: nonLin
 Enter the function by pressing
 Make sure there are no loads on the platform and wait few seconds for stable
indicator on.
 Display will be show
 Load the standard calibration mass weight on the platform and wait
few seconds for display stability.
 Display will be show
After the calibration the display will start a self test. Remove the load from platform
during the test. Display will come to weighing mode automatically.
- 12 -
VC series bench scales Technical Manual
Deci
To set decimal points.
Options: 0 , 0.0 , 0.00 , 0.000 , 0.0000
inc
Di v 1
Di v 2
Cap
Cap 1
Cap 2
Cal
Calibration
To select dual interval
Note: First interval will active in CAP 1
Second interval will active in CAP 2
Deci
To set decimal points
Di v 1
inc
Di v 2
Cap
Cap 1
Cap 2
Cal
Calibration
To select first division
Options: 1 , 2 , 5 , 10 , 20 , 50
To select second division
Options: 1 , 2 , 5 , 10 , 20 , 50
To select first capacity
To select second capacity
To select first division
Options: 1 , 2 , 5 , 10 , 20 , 50
To select second division
Options: 1 , 2 , 5 , 10 , 20 , 50
To select first capacity
To select second capacity
, display will be shown
unload
load
Pass