Avaya Communication Server 1000M Series Upgrade page 65

Meridian 1 51c sg cp piv upgrade
Table of Contents

Advertisement

Table 12
Clock Controller switch settings for QPC471H, QPC771H
Systems upgraded to CP PIV must use the Meridian 1 Option 61C CP PIV switch
settings to enable Clock Hunt software. Use the settings in this table.
SW1
1
2
3
on
on
on
*Total cable length between the J3 faceplate connectors:
0–4.3 m (0–14 ft.)
4.6–6.1 m (15–20 ft.)
6.4–10.1 m (21–33 ft.)
10.4–15.2 m (34–50 ft.)
\** Set to ON for Clock Controller 0. Set to OFF for Clock Controller 1.
Table 13
Clock Controller switch settings for NTRB53 (Part 1 of 2)
Multi Group
Machine
Single group
Type #1
1
2
Multi Group =
21E = Off
Off
51, 61,
Single group =
51C, 61C
On
71, 81,
81C = On
5
Install the Clock Controller in slot 9.
4
1
on
off
Faceplate Cable Length
CC to CC
3
Off
Performing the upgrade
End of Procedure
SW2
2
3
4
off
off
off
4
Off
0-14 Ft.
51C to CS 1000M SG CP PIV Upgrade
Page 65 of 198
SW4
1
2
3
**
on
*
off
off
on
on
Side
Machine
Number
Type #2
5
6
Side 0 =
71,81 = Off
On
21E, 51, 51C,
Side 1 =
61. 61C, 81C
Off
= On
4
*
off
on
off
on

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs 1000m seriesCs 1000m sgCs 1000m mg

Table of Contents