ADC Adtempt 419 Instructions For Use Manual

ADC Adtempt 419 Instructions For Use Manual

Digital hypothermia thermometer

Advertisement

Quick Links

Instructions
for Use
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Adtempt 419 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ADC Adtempt 419

  • Page 1 Instructions for Use...
  • Page 2 ® Adtemp 419 Digital Hypothermia Thermometer ® Thank you for choosing an ADC Adtemp digital stick thermometer. Your new hypothermia thermometer is designed to provide accurate, extended-range body temperature measurements. Adtemp thermometers meet or exceed all relevant international performance standards.
  • Page 3: General Warnings

    General Warnings A warning statement in this manual identifies a condition or practice which, if not corrected or discontinued immediately, could lead to patient injury, illness, or death. WARNING: This instrument is designed for oral, rectal, or axillary use only. WARNING: High prolonged fever requires medical attention, especially for young children.
  • Page 4: How To Use

    How to Use 1. Disinfect the probe with isopropyl (rubbing) alcohol before using. 2. Press and release the multifunction button. The display will read confirming the unit is functioning properly, then will show L°F with °F flashing. 3. We recommend using probe covers with all digital stick thermometers. If using, place cover over tip of unit.
  • Page 5: Charging The Battery

    STOP if you meet any resistance. The sensing unit is on the very tip of the probe and there is no need to insert the probe deep into the rectum. Axillary Use: Wipe armpit with a dry towel. Place the probe in the patient’s armpit (Figure 3) and keep the patient’s arm pressed firmly against the body.
  • Page 6: Cleaning Process

    Cleaning Process 1. Pre-clean with cold water, washing several times. 2. Clean probe with a solution of 5-10% mild detergent for about 10-15 seconds. 3. Continuously clean with cold water to avoid any chemical residues remaining on the device. 4. Rinse the device with drinking water or distilled water to ensure the removal of all remnants of cleansing agent.
  • Page 7: Specifications

    What Is Covered: Replacement of parts, and labor. What Is Not Covered: Transportation charges to ADC. Damages caused by abuse, misuse, accident, or negligence. Incidental, special, or consequential damages. Some states do not allow the exclusion or limitation of incidental, special, or consequential...
  • Page 8 To Obtain Warranty Service: Send item(s) postage paid to ADC, Attn: Repair Dept., 55 Commerce Dr., Hauppauge, NY 11788. Please include your name and address, phone no., proof of purchase, and a brief note explaining the problem. Implied Warranty: Any implied warranty shall be limited in duration to the terms of this warranty and in no case beyond the original selling price (except where prohibited by law).

This manual is also suitable for:

Adtemp 419

Table of Contents