H-3 No-Read Message
Usage:
Definition:
H-3-1
No-Read Message Mode
Serial Cmd:
Default:
Options:
Disabled
Only symbol data is output after a read cycle.
Enabled
When the reader is in a triggered mode, a No-Read message will be appended for each failed read
attempt.
H-3-2
No-Read Message
Definition:
Serial Cmd:
Default:
Options:
• Note: No-Read Message will only be transmitted if Symbol Data Output is set to Match, Mismatch, or Good Read.
No-Read Message can be set to any ASCII character.
MicroHAWK V320-F / V330-F / V420-F / V430-F Barcode Reader User Manual
Used in applications where the host needs serial verification that a symbol
has not been read and especially useful in new print verification.
When enabled, and if no symbol has been decoded before timeout or the
end of the read cycle, the No-Read message will be transmitted to the host.
<K714,No-Read message status,No-Read message>
Enabled
0 = Disabled
1 = Enabled
Any combination of ASCII characters can be defined as the No-Read
message.
<K714,No-Read message status,No-Read message>
NOREAD
A string of up to 64 characters.