3 Controlling Operation and Data Output with Ethernet
3-2-4

Setting the Data to Output after a Read

The code reader can be configured so that after a Read is executed, its read results are automatically
output to the TCP port it is connected to. Additional information such as print quality grade and code
position coordinates can be appended to the Read result output and the format of that output can be
modified.
Change the Read Result Output Condition
You can change the conditions by which you will output your Read results.
• WebLink - Setup - Gear Icon - Advanced Settings - I/O - Symbol Data Output
Setting Item
Symbol Data Output
Output Timing
Set the data to be output when there is a No Read.
You can change the data to output when there is a No Read result.
• WebLink - Setup - Gear Icon - Advanced Settings - I/O - No Read Message
Setting Item
No Read Message
Message
Header and Footer Settings
You can change the Header (Preamble) and Footer (Postamble) that precedes and follows the Read
string.
3 - 32
Setting Value
Disabled
Disabled: Read result is not output.
Match
Match: The Read result is only output when it matches the
Master Symbol set in the Matchcode function.
Mismatch
Mismatch: The Read result is only output when it does not
Good Read
match the Master Symbol set in the Matchcode function.
(default)
Only If All Are
On Good Read: Read results are output for even just one Good
Read.
Good Reads
Only If All Are Good Reads: The Read result is output only
when all the symbols specified in the Read Multiple Symbols
function are successfully read.
As Soon As Pos-
As Soon As Possible: Outputs the Read result immediately on
sible
Good Read and ends the Read Cycle.
(Default)
End of Read Cycle: The Read result is not output until the End
End of Read Cy-
of Read Cycle condition is met. The End of Read Cycle condi-
cle
tion is set in Advanced Settings - Read Cycle - End of Read
Cycle.
Setting Value
Enabled
Enabled:
A message is output when there is a No Read. However, if
(default)
Disabled
the Trigger Mode set in Read Cycle is Continuous Read, no
message is output regardless of this setting.
Disabled:
No message is output for a No Read.
Set the message to output when there is a No Read. You can
NOREAD
(default)
set up to 64 ASCII characters.
V430-F Series Autofocus Multicode Reader User Manual for Communication Settings