6.
Use 4 of the provided M6 x 12 captive pan head screws to attach the bottom housing. Tighten the screws to a
tightening torque of 3.92 to 4.90 N·m (34.69 to 43.37 in-lb).
7.
Remove the necessary conduit knockouts. To remove a conduit knockout, insert the tip of a straight-edge
screwdriver into rectangular hole "A" in
connections marked "B" in
YASKAWA TOEPYAISPC03 UL Type 1 Kit for Single Phase Converter Installation Manual
Figure 2.9 Attach the Bottom Housing
Figure
2.10. Move the screwdriver up and down to break the metal
Figure
2.10.
Figure 2.10 Remove Conduit Knockouts
2 Kit Installation
A
B
B