Adapters For Psa And Sinamics Sitor Interface In Closed-Loop Control Cabinet (Option A25); Adapters For Psa And Sinamics Sitor Interface On Control Compartment (Option A26); Adapters For Psa And Sinamics Sitor Interface In Additional Cabinet (Option A27) - Siemens SINAMICS SL150 6SL39616RC100AA02 Operating Instructions & Installation Instructions

Medium-voltage
Table of Contents

Advertisement

Description
3.2 Options
One power stack adapter (PSA) and one SINAMICS SITOR interface are installed and wired
on each of the three control compartments. One adapter is used in each case for the thyristors
in one phase.
3.2.3
3 adapters for PSA and SINAMICS SITOR interface in closed-loop control cabinet
(option A25)
The adapters adapt the SINAMICS closed-loop control to existing power units employing
SITOR technology. The option is used with the 6-pulse circuit of a three-phase cycloconverter.
One power stack adapter (PSA) and one SINAMICS SITOR interface are installed and wired
on each of the three control compartments. One adapter is used in each case for the thyristors
in one phase. The control panels are mounted in the closed-loop control cabinet.
3.2.4
6 adapters for PSA and SINAMICS SITOR interface on control compartment
(option A26)
The adapters adapt the SINAMICS closed-loop control to existing power units employing
SITOR technology. The option is used with the 12-pulse circuit of a 2 x three-phase
cycloconverter.
One power stack adapter (PSA) and one SINAMICS SITOR interface are installed and wired
on each of the six control compartments. One adapter is used in each case for the thyristors in
one phase.
3.2.5
6 adapters for PSA and SINAMICS SITOR interface in additional cabinet (option
A27)
The adapters adapt the SINAMICS closed-loop control to existing power units employing
SITOR technology. The option is used with the 12-pulse circuit of a 2 x three-phase
cycloconverter.
One power stack adapter (PSA) and one SINAMICS SITOR interface are installed and wired
on each of the six control compartments. One adapter is used in each case for the thyristors in
one phase. The control panels are installed in an additional cabinet.
30
SINAMICS SL150 6SL39616RC100AA02
Operating Instructions Rev.201910281458 EXAMPLE

Advertisement

Table of Contents
loading

Table of Contents