Dsx-1-To-V.35 Configuration - Paradyne HOTWIRE 7924 User Manual

Standalone t1 hdsl termination unit
Hide thumbs Also See for HOTWIRE 7924:
Table of Contents

Advertisement

DSX-1-to-V.35 Configuration

To connect a V.35-compatible unit on the CP side and a DSX-1-compatible unit
on the CO side, configure the units as follows (factory defaults are in bold):
7924-A2-GB20-10
PRELIMINARY DRAFT
Configuration
V.35-Compatible Unit
Option
(Customer Premises)
Card Type
CP
Loops Enabled
Dual (Loops A & B) or
Single (Loop A)
Payload Rate
1 – 9 (64 – 1536 Kbps)
Options 8 (1024) and 9 (1536 kbps)
are only available if Loops A & B are
enabled.
N/A
Framing
N/A
T1 Line Encode
N/A
Line Build-Out
June 1997
Worksheets
DSX-1-Compatible Unit
(Central Site)
CO
Must be same as CP side
N/A
Use D4 or ESF.
B8ZS or AMI
Enter 5 at the Config
command prompt. Select
from the following options:
1) 0 to 133 ft
2) 133 to 255 ft
3) 266 to 399 ft
4) 399 to 533 ft
5) 533 to 699 ft
A-3

Advertisement

Table of Contents
loading

Table of Contents