Paradyne HOTWIRE 7924 User Manual page 25

Standalone t1 hdsl termination unit
Hide thumbs Also See for HOTWIRE 7924:
Table of Contents

Advertisement

Customizing DSX-1-Compatible Units
Displaying Line Build-Out Definitions
Enter 7 at the Config prompt to display the switchpack and board settings for line
build-out. This information is useful if you need to change the line build-out
parameter manually. (Switchpack definitions are also listed in
Jumpers
For example, to change the line build-out to 399 to 533 feet, while in Switchpack
Mode, set position 6 OFF and positions 4 and 5 ON.
4-6
, Appendix C.)
Config
7
*****
SWITCHPACK SETTINGS FOR LINE BUILD OUT
Switchpack Settings
–––––––––––––––––––––––––––––––––––
Position #4 – Bit 0
Position #5 – Bit 1
Position #6 – Bit 2
************ Switchpack Definitions ************
Bit 2
Bit 1
Bit 0 Application
–––––––––––––––––––––––––––––––––––––––––––––––
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
Config
June 1997
OFF=0, ON=1
OFF=0, ON=1
OFF=0, ON=1
0 to 133 feet – 0dB
133 to 266 feet
266 to 399 feet
399 to 533 feet
533 to 655 feet
-7.5 dB
-15 dB
-22.5 dB
Switchpacks and
*******
7924-A2-GB20-10
PRELIMINARY DRAFT

Advertisement

Table of Contents
loading

Table of Contents