Paradyne HOTWIRE 7924 User Manual page 22

Standalone t1 hdsl termination unit
Hide thumbs Also See for HOTWIRE 7924:
Table of Contents

Advertisement

Possible values for each parameter are listed in Table 4-1. See
Appendix A, for help in selecting the appropriate configuration options for your
application.
7924-A2-GB20-10
PRELIMINARY DRAFT
Command
3
Board Configuration:
1) HDSL Card Type
HDSL Rate Type
2) Loops Enabled
3) T1 Line Encode
4) Framing
5) Line Build Out
HDSL FW Rev
AT+T FW Rev
CP Serial #
–––––––––––––––––––––––––––––––––––––––––––––––––––––––
1–5)
Board Configuration
6)
Switch pack Definitions
7)
Line Build–Out Definitions
?)
Redisplays this menu
Q)
Quit
Config
Table 4-1. DSX-1-Compatible Units Configuration Options (1 of 2)
1) HDSL Card Type
Possible Settings: CP, CO
Default Setting: CP
Indicates the placement of the unit in the network configuration. To toggle the card type,
enter 1 at the Config prompt.
CP – Unit is on the customer premises (remote) side of the HDSL connection.
CO – Unit is on the central office (or central site) side of the HDSL connection.
2) Loops Enabled
Possible Settings: Loops A and B, Loop A
Default Setting: Loops A and B
Specifies which loops on the HDSL line are to be used in the connection. To change the
loops that are enabled, enter 2 at the Config prompt. The system then prompts you to
specify either Dual (Loops A and B) or Single (Loop A only).
Loops A and B – Loops A and B are enabled.
Loop A – Only Loop A is enabled.
June 1997
Customizing DSX-1-Compatible Units
– CP
– T1
– Dual Loop (Loops A and B)
– B8ZS
– D4
– 0 to 133 feet, 0dB
– 03
– 1.17
– 085561
Worksheets
,
4-3