Monitoring the Unit
Board Status for V.35-Compatible Unit

Performance Statistics

Performance monitoring allows more detailed observations of error conditions
detected on the circuits. The Performance Monitor menu options provide
statistics on errors received and recorded, in defined time periods from the
previous minute to the previous 24 hours, plus a running total. These statistics
can be cleared and restarted at any time.
Performance statistics update every second.
Accumulated performance statistics may be cleared and restarted by selecting
option 7 on the performance menu.
Enter 2 at the Command prompt to enter the Performance Monitor menu.
6-2
Command
1
DTR:
ACTIVE
DSR:
ACTIVE
LOOPBACK STATUS: OFF
HDSL STATUS:
LOOP A is UP, LOOP B is UP
S/N RATIO:
Loop A = 44.0 dB, Loop B = 43.5 dB.
Command
T1 status displays one of the following: Network is Up, Receive Carrier Loss,
Receive Remote Alarm, or Receive Unframed All 1's.
DTR and DSR are either active or inactive. DSR becomes active in response
to DTR (with HDSL loops up and data transmission possible).
Loopback status is either ON or OFF.
HDSL Status displays whether each loop is up, down, or disabled.
Signal-to-Noise (S/N) ratios do not display if loops are down or disabled.
NOTE:
There is no verification on this command — be sure you want to clear all
statistics before pressing 7!