EN
e.g.
44
SEt
Uhrzeit
448L
0448 L
0563 L
Example:
Inlet water
hardness 20 ° d
Operating range tP1
563 L
Adjusting the soft water supply
Display shows SEt
Display flashes
Adjusting the soft water supply
(only valid for 4° blended water hardness)
Find the litre values from the table, in accordance
with their inlet water hardness and adjusted working
range:
Supply wa-
ter hardness
tP1
°d
litre
10
1500
11
1286
12
1125
13
1000
14
900
15
818
16
750
17
692
18
643
19
600
20
563
21
529
22
500
23
474
24
450
25
429
26
409
27
391
28
375
29
360
30
346
31
333
32
321
33
310
34
300
35
290
Finish programming
The new soft water supply is only displayed after
the next regeneration cycle.
Operating range
tP2
tP3
litre
litre
2166
3000
1857
2571
1625
2250
1444
2000
1300
1800
1182
1636
1083
1500
1000
1385
928
1286
866
1200
812
1125
765
1059
722
1000
682
947
650
900
619
857
591
818
565
783
541
750
520
720
500
692
481
666
464
643
448
621
433
600
419
581
Need help?
Do you have a question about the AQA smart and is the answer not in the manual?
Questions and answers