12. Technical Specification

Pumped Table 3
Part Number
Guarantee
Maximum operating pressure
Ambient temperature range
Specification
Vessel size (litres)
Maximum vessel water storage
capacity (litres)
Height (mm)
Dimensions
Width (mm)
Depth (mm)
Empty weight (Kg)
Weights
Filled weight (Kg)
Maximum weight (Kg)
Pump type
Pump model
Pump
Mechanical seal
Pump body/impeller
Enclosure protection
Motor
Duty rating
Power supply/phase/frequency
Current (Full load)
Electrical
Power consumption
Fuse Rating
Power cable
Connections
Anti vibration couplers
Maximum head
Maximum flow rate
Performance
Time at maximum flow rate
Minimum continuous flow rate
20
ACC-060-SYS
55
27.5
675
457
480
15.4
42.9
70.4
Type
Pump
14 L/min
9 mins
12 L/min
Performance values may be higher if mains natural flow is above 12 L/min
Note: quoted values may vary due to tolerances and site conditions.
ACC-120-SYS
ACC-180-SYS
3 years
8.6 Bar/860 kPa
4°C to 49 °C
112
178
56
89
1126
1081
457
557
480
557
20
27.5
76
116.5
132
205.5
Regenerative
ASSYACCUFORCE
Nitrile/carbon/ceramic
Brass
IPX2
Capacitor start and run induction motor
Continuous
230 V/1/50 Hz
1.9 A
410 W
3 A
Pre-wired with plug
3/4" male BSP
3/4" female BSP - 22mm push-in
4 Bar/400 kPa
16 L/min
18 L/min
9 mins
9 mins
12 L/min
12 L/min
ACC-300-SYS
ACC-450-SYS
301
453
150.5
226.5
1633
1863
557
651
557
635
42.7
54.2
193.2
280.7
343.7
507.2
30 L/min
36 L/min
9 mins
9 mins
12 L/min
12 L/min

Advertisement