Advertisement

Pump Installation and Warranty Guide
1

Advertisement

Table of Contents
loading

Summary of Contents for Salamander Pumps EVE

  • Page 1 Pump Installation and Warranty Guide...
  • Page 2 Pump installation and warranty guide for EVE Important – read this first! Safety in Operation These appliances are not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience or knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Page 3: Table Of Contents

    Contents What can EVE do? Getting to know EVE Assembling EVE Pre-installation checklist Installation instructions Typical installations Operating instructions Mode selection General specification Trouble shooting PumpWise and warranty To the installer...
  • Page 4: What Can Eve Do

    What can EVE do? 1. EVE has an EPV – Electronic Pressure Vessel. This monitors the system pressure and when a slow small leak is detected it automatically re-pressurises the system 2. EVE has 3 selectable modes 1.5bar 2.0bar 3.0bar 3.
  • Page 5: Getting To Know Eve

    Getting to know EVE Hot or cold outlet Hot or cold outlet Hot or cold inlet Hot or cold inlet MODE panel Warranty information Rating label X4 Vibration dampening feet...
  • Page 6 X2 Angled 22mm coupler with iso push fit 13. ERROR lights 9A. Isolation valve 14. Power indicator 9B. Pipe release collar 15. MODE selector 10. X2 Straight 22mm coupler with iso push fit 16. MODE 1 11. X2 Outlet rubber washers 17.
  • Page 7: Assembling Eve

    Assembling EVE...
  • Page 8: Pre-Installation Checklist

    The maximum static head should be 10m another pump (equivalent to 100kPa/1.0 bar pressure) Never connect to a secondary return EVE will automatically activate for tapping on a hot water cylinder 3 seconds after 24 hours of inactivity without a dip tube...
  • Page 9: Installation Instructions

    Installation Instructions Plumbing Electrical The installation must comply with the relevant The electrical installation must be carried out in accordance with the current national requirements or local bye-laws. electrical regulations (BS 7671:2018, Building The pump MUST be mounted upright (shaft (Scotland) Act 2003, or Building Regulations horizontal –...
  • Page 10: Typical Installations

    LOFT MOUNTED PUMPS MUST BE PROTECTED AGAINST FROST DAMAGE. EVE installed at the base of the hot water cylinder These numbers relate to figure 1 Cold water storage tank fitted to current standards – capacity should be enough for your requirements per bathroom or per shower room or en-suite –...
  • Page 11 Figure 1.
  • Page 12 Figure 2.
  • Page 13: Operating Instructions

    EVE installed above the hot water cylinder These numbers relate to figure 2. All up and over pipe work must be vented at the highest point on the outlet of the pump. The pump should be fitted at least 600mm below the base of the cold water tank.
  • Page 14: Mode Selection

    3bar by static speed performance. To change the mode: N.B. - The mode can only be changed whilst the EVE is ON and not running (no flow). TOUCH and HOLD the MODE selector Every time the next mode is selected, the LED until the next mode LED comes on ring flashes and the mode selected stays lit.
  • Page 15: General Specification

    Tank Specification EVE’s enhanced dynamic performance enables multiple outlet to be fed with a set pressure. To enable this performance please ensure the system has enough stored water. The table below shows how long different volumes of water will last at maximum flow rate. Max flow will occur where multiple outlets are open, e.g, 2 showers or bath and shower.
  • Page 16 Pump Mode General Guarantee 3 years Features Pump type Centrifugal Mechanical seal Nitrile/Carbon/Ceramic Inlet isolator(s) Included Flexible hose Dry run protection Included Performance Pressure @ 16lpm 1.5bar 2bar 2.7bar Pressure @ 8lpm 1.5bar 2bar 2.85bar Pressure @ closed 1.5bar 2bar 3bar Maximum water temperature 65°C...
  • Page 17: Trouble Shooting

    Protection has been initiated, and the pump has locked out. Flash EVE is detecting aeration or water Find the restriction on input flow, or air leak, and starvation in pump chambers. repair. Once the issue has been identified and...
  • Page 18 Fault Probable cause Recommended solution Pump will not start Electrical Check power supply Check fuse Check circuit breaker Inlet/outlet connections Check that connections are plumbed the correct incorrect way round and all valves are open Float sticking in outlet Ensure no debris is in outlet area Flow switch malfunction Contact our technical advisors on 0191 516 2002 Reduced/...
  • Page 19: Pumpwise And Warranty

    Monday to Thursday 8.00am to 5.30pm Your warranty Friday 8.00am to 5.00pm. Salamander customers benefit from a full 3 year warranty on EVE. PumpWise is the cornerstone of Salamander Pumps support service to customers and This warranty will operate from the date of...
  • Page 20: To The Installer

    To the installer Please follow the guidelines for installation You are the original purchaser of the equipment from a dealer and not an assignee or subsequent purchaser of provided in this brochure and call the the equipment. PumpWise helpline for installation advice. You must evidence the date of purchase by retaining the Once installation has been completed and the original invoice from the dealer.
  • Page 21 Notes...
  • Page 22 Notes...
  • Page 23 Notes...
  • Page 24 Get in touch, we’re here to help Get in touch, we’re here to help call us on 0191 516 2002 call us on 0191 516 2002 Unit 2c Colima Avenue Unit 2c Colima Avenue Enterprise Park West Enterprise Park West Sunderland, SR5 3XE Sunderland, SR5 3XE Register your warranty...

Table of Contents