6.6 Electrical installation (pumped versions only)

Your pump must be connected to the electrical supply using the supplied mains cable with the
attached plug. This plug must be connected to an accessible socket that has been installed in
compliance with IET Wiring Regulations.
- The plug must be accessible at all times
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent,
or similarly qualified person in order to avoid a hazard.
- All pipework must be cross bonded in accordance with IET Regulations
- The pump is supplied with a 3A fuse fitted. A higher rate fuse must not be fitted.
- If installed by a Part P qualified installer, the pump may be fitted via a fused main spur
containing a 3A fuse without invalidating the warranty.
- The pump must be connected to earth via the plug/supply cord.
- The mains lead wires are coloured as follows:
- The electrical circuit must contain a suitable R.C.D.
- Water should not be allowed to come into contact with the pump or the supply cable.
- If the unit is to be installed in a loft, garage, outbuilding or other location where there is
a risk of water ingress or condensation to the socket, an appropriately IP rated socket
must be used.
- Bathroom Zones: Salamander products covered in these notes cannot be installed in Zone
0 or Zone 1. See Figure 9
- The unit should be installed in accordance with BS7671:2018
- In BS7671:2018 rooms containing baths or showers should be broken down into zones
- These zones are summarised as:
ZONE 0 - This is the bath or shower tray
ZONE 1 - Is considered to be the area where the individual is bathing or showering or the
area where shower water is likely to be directly sprayed.
ZONE 2 - Is the area beyond ZONE 1, extending by a further 600mm
Outside
Zones
2
2
2
0.6m
2
1
1
2
12
Brown = Live
Please refer to BS7671:2018 for further guideance
Outside
Zones
0.6m
2
Zone 0
Zone 1
Zone 2
Outside Zone
Space under bath is Zone 1
if accessible without tool
Window recess Zone 2
Blue = Neutral
Figure 9
Outside
Zones
Green & Yellow = Earth
2
0.6m
2
0.6m
2
1
2
0
2
Outside Zones
Outside
Zones
Zone 0
Zone 1
Zone 2
Outside Zone
Space under bath is Zone 1
if accessible without tool
Window recess Zone 2