Pump installation and warranty
guide for the CT range of pumps
CT Force, CT Xtra, and CT Bathroom
This document should be given to the end user and retained for future reference.
Should you need to contact Salamander Pumps you will need the below information.
Models shown:
CT FORCE 15TU
CT50+ Xtra

Advertisement

Table of Contents
loading

Summary of Contents for Salamander Pumps CT FORCE 15TU

  • Page 1 CT range of pumps CT Force, CT Xtra, and CT Bathroom This document should be given to the end user and retained for future reference. Should you need to contact Salamander Pumps you will need the below information. Models shown: CT FORCE 15TU...
  • Page 2 Please leave this instruction booklet with the customer for reference to maintenance, safety information and details of warranty cover. Thank you for choosing Salamander Pumps. Safety in Operation These appliances are not for use by persons (including children) with reduced physical,...
  • Page 3: Table Of Contents

    Contents CT FORCE range of pumps CT Xtra range of pumps CT Bathroom range of pumps Product description Installation instructions Step 1: Pump location Step 2: Connecting the pump Step 3: Electrical installation PumpWise Guidelines General specifications Technical specifications Trouble shooting Salamander PumpWise Warranty...
  • Page 4 Pre-installation Checklist Our installation guidelines are detailed on the following pages, but some of the key “do’s and don’ts” are highlighted below: Do’s • Locate the pump next to the hot water cylinder or within 5m of measured pipe. 2m maximum of 15mm pipework on inlet connections may be used •...
  • Page 5 Pre-installation Checklist (continued) Don’ts  Never fit the pump to the cold water mains  Never fit the pump to shared incoming mains supplies to a block of flats  Never use a shared water supply or shared, communal cold water storage cistern  Never put a non-return valve (NRV), restrictive ballofix or an air vent on supply pipe work to the pump  The hot water supply must not exceed temperature stated in the installation guide...
  • Page 6: Product Description

    Any queries should be directed to PumpWise on 0191 516 2002 (01844-3212 ROI). Do not use Salamander pumps for applications other than those stated within the pump description, or connect the pump directly to the cold mains.
  • Page 7 of the cisterns level. Never put a non-return valve, restricted ballofix or an air vent on the supply pipework to the pump. The stored hot water temperature must not exceed 60ºC. Ensure that the hot supply to the pump is via a Salamander approved method. (Figure 2, 4 & 5 Pages 5&7).
  • Page 8: Step 1: Pump Location

    Step 1: Pump location 1. Site the pump in a location where it will not freeze or be exposed to frost during cold weather. 2. Ensure adequate airflow to cool the motor. Separate the pump from other appliances that generate heat. Install the pump in a clear space allowing 100mm at each side, end and top. 3.
  • Page 9 8. Check the marker arrows on the pump to ensure correct direction of water flow. Either end of the pump is suitable for hot or cold water. 9. Check the static inlet pressure does not exceed 10m max (1.0bar/100kPa) of water above the pump.
  • Page 10 Negative head systems Negative head systems exist where insufficient natural flow of water goes to the outlet because either the outlet or the pipework to the outlet are above the height of the base of the cold water cistern. Most instances of negative head systems occur in loft conversions or where the cold water cistern sits on the joists in the loft.
  • Page 11 Commissioning Before you finish Fit pump inlet filters and vibration dampening feet. It is CRITICAL to discharge water through the pump into a container using natural flow before connecting the pump to outlet pipework in order to ensure the air has been discharged from inlet pipework and pump chambers.
  • Page 12: Step 2: Connecting The Pump

    Step 2: Connecting the pump Use only Salamander supplied AV couplers to connect the pump. All associated pipework MUST be thoroughly flushed before making final connections to the pump. Fill the pump with water before connecting to the discharge pipework. The in-line strainers must be fitted to the hot and cold inlet supplies to the pump.
  • Page 13: Step 3: Electrical Installation

    Step 3: Electrical installation Your pump must be connected to the electrical supply using the main cable with the attached plug. This plug must be connected to an accessible socket that has been installed in compliance with IET Wiring Regulations. The plug must be accessible at all times.
  • Page 14: Pumpwise Guidelines

    Helpful guidelines Cold water supplies and storage Recovery of cold storage Ensure that there is sufficient water recovery to cover the water usage by the appliance. Aeration of pump and cylinder from a cold water storage cistern This occurs when the incoming cold mains ball valve is positioned above the cold feeds to the cylinder and to the pump –...
  • Page 15 Figure 9: Water starvation protection unit Water starvation protection (WSP) In systems where it is absolutely not possible to increase the usable cold water storage capacity to meet the increased demand of a pumped system; a water starvation protection unit (WSP) may be considered (See fig 9).
  • Page 16 Figure 11: Approved flanges Approved flanges (cylinders) The 22mm No Stop Essex and the other approved top entry flanges with extension pipes into the cylinder represent the best Usable capacity known means of ensuring minimal aeration minimum 50 gallons per bathroom of the hot supply water to the pump.
  • Page 17 Pump hunting protection In negative head systems all the discharge pipework after the pump is pressurized. In such systems there exists the possibility the pump will hunt ON-OFF-ON etc. at intervals. This will happen: • if all outlets are not fully closed •...
  • Page 18 HWS TMV blending valve controller A Salamander approved HWS Blending valve controller will protect booster pumps in systems where the temperature of the stored hot water is uncontrolled or crudely controlled via boiler thermostat only – see below. Figure 13: HWS blending valve controller to pump Usable capacity minimum 50 galls per bathroom...
  • Page 19: General Specifications

    General specifications – CT FORCE Applications All Salamander pumps are designed to boost low pressure hot and cold supplies from cistern- fed services. When supplies from a water heater or a combination boiler are to be boosted contact the Salamander PumpWise helpline on 0191 516 2002 for guidance.
  • Page 20 General specifications – CT Xtra & CT Bathroom Applications All Salamander pumps are designed to boost low pressure hot and cold supplies from cistern-fed services. When supplies from a water heater or a combination boiler are to be boosted contact the Salamander PumpWise helpline on 0191 516 2002 for guidance.
  • Page 21: Technical Specifications

    Technical specifications - CT Force Part No. Description Specification Performance Connection Type Pump Volumetrics Packed Pump Volumetrics Electrical Pump Pump Hoses Isolators Dimensions Dimensions Input Type CT FORCE ¾” Force 15PT 1.5 Bar Twin End 22mm    Force 15IPT Positive Head Shower (1.1) (1.3)
  • Page 22 Technical Specifications - CT Xtra Part No. Description Specification Performance Connection Type Pump Volumetrics Packed Pump Volumetrics Electrical Pump Pump Hoses Isolators Dimensions Dimensions Input Type CT Xtra Shower Pumps ¾” CT50+ Xtra 1.5 Bar Twin End 15mm   ...
  • Page 23 Technical Specifications - CT Xtra H & HU, CT Bathroom B & BU Part No. Description Specification Performance Connection Type Pump Volumetrics Packed Pump Volumetrics Electrical Pump Pump Hoses Isolators Dimensions Dimensions Input Type CT Bathroom & CT H Xtra Shower Pumps CT60 B 1.8 Bar Twin End ¾”...
  • Page 24: Trouble Shooting

    Trouble Shooting CHECK THAT THE INSTALLATION COMPLIES WITH THE SALAMANDER INSTRUCTIONS IF THE PUMP IS STILL INOPERABLE, CONTACT PUMPWISE ON 0191 516 2002. Fault Probable cause Recommended solution Pump will not start Insufficient gravity flow Check suitability of pump – is installation in negative head (see page 8) Check inlet filters are not blocked Check flow rate (min of 2l/min required on both hot and cold)
  • Page 25: Salamander Pumpwise

    Salamander Salamander PumpWise is your guarantee to: • help you select the right pump for the job. • avoid installation pitfalls. PumpWise helpline 0191 516 2002 PumpWise from Salamander helps customers and provides a support service second to none. Installers and customers can be sure of a speedy response to requests for technical help, guidance and advice.
  • Page 26: Warranty

    PLEASE NOTE: Incorrect installation WILL invalidate the pump warranty Salamander Pumps operates a policy of continuous development and reserves the right to change any of the specifications of its products without prior notice. All information data and illustrations given in this leaflet may be subject to variation.
  • Page 27 Once the installation has been completed and the system has been tested to your satisfaction, please assist the customer in completing warranty registration. Please note that Salamander Pumps are able to provide an on-site service visit which may be chargeable.
  • Page 28 c. You must evidence the date of purchase by retaining the original invoice from the dealer. Without such evidence the Company reserves the right to reject any such claims under the terms of this Warranty. d. Within 15 days of purchase of the equipment the Warranty registration is accurately completed online or over the telephone.
  • Page 29 e. This Warranty is given in addition to and does not affect your statutory rights as a consumer. f. This Warranty is valid and enforceable for equipment purchased and used exclusively in the UK and The Republic of Ireland only. g.
  • Page 30 Notes...
  • Page 31 Notes...