Pump installation and warranty
guide for the CT range of pumps
CT Force, CT Xtra, and CT Bathroom
Models shown:
CT FORCE 15TU
CT50 Xtra
CT60B

Advertisement

Table of Contents
loading

Summary of Contents for Salamander Pumps CT Force

  • Page 1 Pump installation and warranty guide for the CT range of pumps CT Force, CT Xtra, and CT Bathroom Models shown: CT FORCE 15TU CT50 Xtra CT60B...
  • Page 2: Table Of Contents

    Pump installation and warranty guide Contents for the CT range of pumps CT FORCE range of pumps Important - read this first! CT Xtra range of pumps Product description Correct installation is the guarantee of safety and a trouble free system. It is therefore important to read these instructions thoroughly and ensure you comply with them.
  • Page 3 Pre-installation Checklist Pre-installation Checklist (continued) Our pre-installation guidelines are detailed on the following pages, but some of the key Don’ts “do’s and don’ts” are highlighted below:  Never fit the pump to the cold water mains Do’s  Never fit the pump to shared incoming mains supplies to a block of flats  Locate the pump next to the hot water cylinder within 5m of measured pipe.
  • Page 4: Product Description

    Xtra 64H, 69H & 84H are whole house pumps Min 600mm • CT FORCE 15 TU, 15 ITU, 20 TU, 20 ITU, 20 SU, 20 ISU, 30 TU, 30 ITU, 30 SU & 30 ISU, Air vents, both hot CT Bathroom, 60BU & 80BU , and CT Xtra 64 HU, 69HU & 84HU are universal pumps.
  • Page 5: Step 1: Pump Location

    8. Check the marker arrows on the pump to ensure correct direction of water flow. Step 1: Pump location Either end of the pump is suitable for hot or cold water. 9. Check the static inlet pressure does not exceed 10m max (1.0bar/100kPa) of water above the pump.
  • Page 6 CT FORCE 15 TU, 20 TU, 20 SU, 30 TU and 30 SU, and CT Bathroom 60BU & 80BU. Irish CT pumps suitable for negative head operation are: CT FORCE 15 ITU, 20 ITU, 20 ISU, 30 ITU and 30 ISU, and CT Xtra 64HU, 69HU & 84HU. The hot connection must be via an approved side or top entry flange...
  • Page 7: Step 2: Connecting The Pump

    Step 2: Connecting the pump Step 3: Electrical installation Use only Salamander supplied AV couplers to connect the pump. Your pump must be connected to the electrical supply using the main cable with the attached plug. This plug must be connected to an accessible socket that has been installed in All associated pipework MUST be thoroughly flushed before making final connections compliance with IET Wiring Regulations.
  • Page 8 Helpful guidelines Figure 11: Water starvation protection Water starvation protection unit (WSP) In systems where it is absolutely not possible to increase the usable cold water storage capacity to meet the increased Cold water supplies and storage Recovery of cold storage demand of a pumped system;...
  • Page 9 (e.g. tapstat). a pressure vessel unit, into the supply pipework as close as possible to the outlet from which Maximum water temperature for CT Xtra, CT Bathroom & CT FORCE pumps is 65ºC. the shock waves are originating.
  • Page 10: General Specifications

    – see below. Applications All Salamander pumps are designed to boost low pressure hot and cold supplies from cistern- Figure 16: HWS blending valve controller to pump fed services. When supplies from a water heater or a combination boiler are to be boosted contact the Salamander PumpWise helpline on 0191 516 2002 for guidance.
  • Page 11: Technical Specifications

    General specifications – CT Xtra & CT Bathroom Technical specifications - CT Force Applications All Salamander pumps are designed to boost low pressure hot and cold supplies from Part No. Description Specification Performance Connection Type Pump Volumetrics Packed Pump Volumetrics cistern-fed services.
  • Page 12 Technical Specifications - CT Xtra Technical Specifications - CT Xtra H & HU, CT Bathroom B & BU Part No. Description Specification Performance Connection Type Pump Volumetrics Packed Pump Part No. Description Specification Performance Connection Type Pump Volumetrics Packed Pump Volumetrics Volumetrics Electrical...
  • Page 13: Trouble Shooting

    Trouble Shooting Salamander CHECK THAT THE INSTALLATION COMPLIES WITH THE SALAMANDER INSTRUCTIONS IF THE Salamander PumpWise is your guarantee to: PUMP IS STILL INOPERABLE, CONTACT PUMPWISE ON 0191 516 2002. • help you select the right pump for the job. Fault Probable cause Recommended solution...
  • Page 14: Warranty

    Warranty To the installer Salamander CT FORCE brass ended pumps benefit from a full five years warranty, CT Xtra Please follow the guidelines for installation provided in this brochure and call the PumpWise and CT Bathroom pumps benefit from a full three years warranty (UK only).
  • Page 15 The Warranty periods referred to in paragraph 1 above are as follows: a. i. CT FORCE (UK only) products manufactured by the Company 5 years from date of purchase provided the warranty registration is completed online or over the phone within 15 days of purchase.
  • Page 16 Notes Notes...