11. Multiple Vessels

If additional water storage capacity is required, multiple vessels can be installed in a system.
NOTE: ONLY ONE PUMP CAN BE FITTED PER INSTALLATION. Additional vessels should be
connected via a "T" on the vessel port of the pump (for pumped versions). A Salamander
Pumps vessel connector kit (part code TNK-CON-KIT) can be purchased separately to allow
multiple vessels to be connected. The precharge air pressure within all vessels in the system
should be set to the same value.
Please see typical installation examples below: -
Unpumped
Recommended upstream
plumbing (not supplied)
Double
Stop
Inline
check
cock
strainer
valve
Pumped
Recommended upstream
plumbing (not supplied)
Double
Pressure
Stop
check
reducing
cock
valve
valve
Note: In all instances, the installation must comply with the latest water, electrical and building regulations
18
Figure 18
Maintenance
(isolating valve
Pressure
not supplied)
reducing
valve
Figure 19
Maintenance
bypass
(isolating valves
not supplied)
Combi Boiler/
bypass
Combi Boiler/
Outlets
Unvented
Cylinder
Outlets
Unvented
Cylinder