Salamander Pumps FORCE 15 PT Installation And Warranty Manual

Salamander Pumps FORCE 15 PT Installation And Warranty Manual

Pump installation and warranty guide for the force range of pumps

Advertisement

ISSUE 1 JANUARY 2011
Pump installation and
warranty guide for the
FORCE range of pumps
FORCE 15 PT, 15 IPT, 15 TU, 15 ITU
FORCE 20 PT, 20 IPT, 20 TU, 20 ITU,
20 PS, 20 IPS, 20 SU, 20 ISU
FORCE 30 PT, 30 IPT, 30 TU, 30 ITU,
30 PS, 30 IPS, 30 SU, 30 ISU

Advertisement

Table of Contents
loading

Summary of Contents for Salamander Pumps FORCE 15 PT

  • Page 1 Pump installation and warranty guide for the FORCE range of pumps FORCE 15 PT, 15 IPT, 15 TU, 15 ITU FORCE 20 PT, 20 IPT, 20 TU, 20 ITU, 20 PS, 20 IPS, 20 SU, 20 ISU FORCE 30 PT, 30 IPT, 30 TU, 30 ITU,...
  • Page 2 Push-fit attachment Isolation valves 22mm stainless steel braided anti-vibration couplers Brass nuts Rubber sealing washers (on the outlets) Filter washers (on the inlets) Water outlets Water inlets Pump motor Pump housing Rubber feet...
  • Page 3 Pump installation and warranty guide for the FORCE range of pumps FORCE 15 PT, 15 IPT, 15 TU, 15 ITU FORCE 20 PT, 20 IPT, 20 TU, 20 ITU, 20 PS, 20 IPS, 20 SU, 20 ISU FORCE 30 PT, 30 IPT, 30 TU, 30 ITU, 30 PS, 30 IPS, 30 SU, 30 ISU Important –...
  • Page 4 FORCE 15 A range of brass ended 1.5 bar shower pumps – ideal for boosting shower performance FORCE 15 PT, FORCE 15 IPT 1.5 bar twin brass ended positive head shower pump FORCE 15 TU, FORCE 15 ITU 1.5 bar twin brass ended positive and negative head universal shower pump FORCE 20 A range of brass ended 2.0 bar shower pumps...
  • Page 5: Table Of Contents

    Installation Specifications Trouble shooting PumpWise Warranty Contents FORCE range of pumps Product description Installation instructions Step 1: Pump location Step 2: Connecting the pump Step 3: Electrical installation General specifications Technical specifications Trouble shooting Salamander PumpWise Warranty...
  • Page 6: Product Description

    Please note that: in 28mm pipework. • FORCE 15 PT, 15 IPT, Multiple cold water storage tanks must be FORCE 20 PT, 20 IPT, 20 PS, 20 IPS, linked in 28mm pipework with the bottoms FORCE 30 PT, 30 IPT, 30 PS and 30 IPS of the tanks level.
  • Page 7: Step 1: Pump Location

    Installation Specifications Trouble shooting PumpWise Warranty Step 1: Pump location The stored hot water temperature must not exceed 65ºC. 1 Site the pump in a location where it will Ensure that the hot supply to the pump is via not freeze or be exposed to frost a Salamander approved method.
  • Page 8 Installation Specifications Trouble shooting PumpWise Warranty Figure 6. Tee off other supplys 10 Check the marker arrows on the pump to ensure correct direction of water flow. Either end of the pump is suitable for hot Cold water storage or cold water. 11 Check the static inlet and outlet heads 2 litres/min natural flow...
  • Page 9 Installation Specifications Trouble shooting PumpWise Warranty Negative head systems Negative head systems are where no natural flow of water goes to the shower head because it is above the height of the base of the cold water tank. Most instances of negative head systems occur in loft conversions or where the cold water tank sits on the joists in the loft.
  • Page 10: Step 2: Connecting The Pump

    Installation Specifications Trouble shooting PumpWise Warranty Step 2: Connecting the pump 35° Use only Salamander supplied hoses to Do not bend hoses more than 35° connect the pump. The in-line strainers must be fitted to the hot and cold inlet supplies to the pump. It is critical to discharge water through the pump into a container before connecting the pump to outlet pipework in order to...
  • Page 11: Step 3: Electrical Installation

    Installation Specifications Trouble shooting PumpWise Warranty Step 3: Electrical installation All electrical installations must be carried out in accordance with applicable regulations by a suitably qualified electrician. The pump must be connected to the electrical supply using the mains cable with the attached plug.
  • Page 12: General Specifications

    Applications element with ceramic counter face) are used. Scale deposits in water supplies can All Salamander pumps are designed to cause the mechanical seal to stick if left boost low pressure hot and cold supplies for long periods without use. Salamander from tank-fed services.
  • Page 13: Technical Specifications

    Installation Specifications Trouble shooting PumpWise Warranty Technical specifications Packed Pump Part No Description Specification Performance Connection Type Pump Volumetrics Volumetrics Electrical Pump Pump Hoses Isolators Dimensions Dimensions Input Type Positive Head FORCE 15 TP 1.5 Bar Twin End Positive ¾ " 22mm 6.3 220 120 195 7.8 310 210 220 FORCE 15 ITP Head Shower Pump FORCE 20 TP 2.0 Bar Twin End Positive...
  • Page 14: Trouble Shooting

    Installation Specifications Trouble shooting PumpWise Warranty Trouble shooting Fault Probable cause Recommended solution Pump will not Insufficient gravity flow Check that installation complies with Salamander instructions start Check suitability of pump – is installation in negative head (see page 7) Check inlet filters are not blocked Check flow rate min of 2l/min required on both hot and cold Inlet/outlet connections...
  • Page 15: Salamander Pumpwise

    Installation Specifications Trouble shooting PumpWise Warranty Salamander PumpWise Safety in operation These appliances are not intended for use Salamander PumpWise is your guarantee to: by persons (including children) with reduced • help you select the right pump for the job. physical, sensory or mental capabilities, •...
  • Page 16: Warranty

    Facsimile: 0191 548 4445 invalidate the pump warranty E-mail: tech@pumpwise.co.uk Salamander Pumps operates a policy of continuous development and reserves the To the installer right to change any of the specifications Please follow the guidelines for installation of its products without prior notice.
  • Page 17 Installation General Specifications Trouble shooting PumpWise Warranty 1 The Scope of the Warranty person dealing as a consumer all warranties, conditions or other terms implied by law SALAMANDER PUMPED SHOWER are excluded to the fullest extent permitted SYSTEMS LTD (“the company”) Warrants by law.
  • Page 18 Installation Specifications Trouble shooting PumpWise Warranty 3 The Warranty periods e This Warranty is given in addition to and does not affect your statutory rights as The Warranty periods referred to in a consumer. paragraph 1 above are as follows: f This Warranty is valid and enforceable a Products manufactured by the Company for equipment purchased and used...

Table of Contents