Salamander Pumps CombiBoost Installation Manual

Hide thumbs Also See for CombiBoost:

Advertisement

Quick Links

Pump installation and warranty
guide for CombiBoost

Advertisement

Table of Contents
loading

Summary of Contents for Salamander Pumps CombiBoost

  • Page 1 Pump installation and warranty guide for CombiBoost...
  • Page 2 Pump installation and warranty guide for CombiBoost Important – read this first! The CombiBoost has two separate and distinct applications. The first is for use on the incoming domestic cold water mains supply, and the second is directly on the combi-boiler cold water inlet.
  • Page 3: Table Of Contents

    Contents Pre-installation checklist Application notes Typical installations Commissioning General specifications Troubleshooting Fittings kit PumpWise and warranty To the installer Terms and conditions 12-13...
  • Page 4: Pre-Installation Checklist

    Pre-installation checklist CombiBoost is suitable for two separate types of water boosting applications 1. Boosting the incoming mains water supply to a whole house 2. Boosting the inlet mains water supply solely to a combination (combi) boiler. Points applicable to either installation type: Do’s...
  • Page 5: Application Notes

    1. Location of CombiBoost The best possible location of the CombiBoost is on the cold water mains supply to the house, by the mains stop tap or the combi boiler inlet, depending on the installation.
  • Page 6 To hold the CombiBoost during installation, spanner flats (24mm) have been provided on the brass neck outlet. See Figure 1. Any tool used to hold the CombiBoost while the pipework is connected must be located on the brass portion of the neck to avoid damage to the polymer pump body.
  • Page 7: Typical Installations

    Typical installations Figure 2: Inlet and outlet Figure 5: Typical installation locations NOTE: Refer to pre-installation checklist for suitability Outlet Combi-boiler Combi-boiler Inlet Figure 3: Ideal location Figure 6: Earth continuity (4mm earth connection cable) Isolating Combi-boiler Ball valve Isolation valve for combi-boiler Tap connector Tap connector...
  • Page 8: Commissioning

    Before you finish • Check the pump inlet filter is fitted • With the CombiBoost installed, flush the inlet pipe work and fully fill the pump with water by opening all the water outlets BEFORE electrically switching the pump on.
  • Page 9: General Specifications

    CombiBoost will increase the low incoming water flow up to 10 l/min which complies with the Water Supply (Water Fittings) Regulations 1999. As the incoming flow varies, the CombiBoost will adapt to maintain 10 l/min, and will move into idle if sufficient flow is received from the water main.
  • Page 10 • EN 60335-1:2002 and EN 60335-2-41:2003 Household and similar electrical appliances – safety (Part 1 General requirements and Part 2-41 Particular requirements for pumps). The company operates a policy of continuous development and reserves the right to change any of the specifications of its products without prior notice. All information data and illustrations given in this leaflet may be subject to variation.
  • Page 11: Troubleshooting

    Troubleshooting Fault Probable cause Recommended solution Pump will not start Electrical Check power supply (appliance plugged in and electrical power on) Check fuse Check circuit breaker Inlet/Outlet Check that the connections are plumbed in the correct way round and all connections valves are open Insufficient mains flow...
  • Page 12: Fittings Kit

    Fittings kit (not included) Purchase separate - ACCHBFIT01 from https://shop.salamanderpumps.co.uk/ Contents 1 x Ball valve 1 x tap connector 2 x reducer ¾” Tap connector x ¾” Tap connector x 22mm x 15mm 22mm compression 22mm compression compression reducer Fitting instructions Flat Flat washer...
  • Page 13: Pumpwise And Warranty

    Installers and consumers can be sure of a speedy response to requests for technical help, guidance, and advice. Your warranty Salamander customers benefit from a return to factory one year warranty on the CombiBoost pump. This warranty will operate from the date of purchase and is subject to the installation guidelines being followed correctly (please refer to our Pre-Installation checklist and our Commissioning checklist).
  • Page 14: To The Installer

    To the installer Please follow the guidelines for the installation provided in this brochure and call the PumpWise helpline for installation advice. Once installation has been completed and the system has been tested to your satisfaction, please assist the customer by giving them the information needed to complete the online warranty registration.
  • Page 15 You are the original purchaser of the equipment from a dealer and not an assignee or subsequent purchaser of the equipment. You must evidence the date of purchase by retaining the original invoice from the dealer. Without such evidence the Company reserves the right to reject any such claims under the terms of this Warranty.
  • Page 16 Get in touch, we’re here to help call us on 0191 516 2002 Unit 2c Colima Avenue Enterprise Park West Sunderland, SR5 3XE Register your warranty Apply online at: www.salamanderpumps.co.uk Apply by phone: 0191 516 2002...

Table of Contents