Technical data
11.1
Technical data
Technical data
General technical data and information about the mechanical and climatic environmental
condition of the ET 200pro system is provided in the "SIMATIC ET 200pro Distributed I/O
System" manual.
Note
Deviating from this general technical data, for the ET 200pro FC-2 inverter, the following
applies:
Drop test (in original package) ≤ 0.35 m.
Table 11- 1
Date
Rated input voltage
Permissible voltage range min.
Permissible voltage range max.
Rated output current
@ 45 °C
@ 55 °C
Maximum output current (3 s)
Rated input current 3AC
Integrated device fuse
Rated power @ 55 °C
Power with overload (150% for 60 s every 300 s)
Power with overload (200% for 3 s every 300 s)
Power without overload capability
Integrated brake control
Maximum current of the brake control
Pulse frequency (factory setting)
Installation altitude above sea level
Efficiency η
Power factor
Mechanical data
SIMATIC ET 200pro FC-2 converter
Operating Instructions, 04/2018, FW V4.7 SP10, A5E34257324B AF
Technical data
Unit
Value
V
AC 400
V
AC 380
V
AC 480
A
3.9
A
3.5
A
2 x rated output current
A
3.7
A
16, medium time-lag
kW
1.10
kW
1.65
kW
2.20
kW
1.20
V
DC 200
A
1.0
kHz
4
m
2000
%
95 ... 97
---
0.9
11
245