Signal Processing; Figure 3-8 Logical Design Of The Dm10 Diagnosis Module - Siemens SINAMICS SM150 6SL3810-7NN38-0AA1 Operating And Installation Instructions

Medium-voltage drive
Table of Contents

Advertisement

Figure 3-8
Logical design of the DM10 diagnosis module
See also
LEDs of the DM10 diagnostics module (Page 135)
3.5.13.2

Signal processing

Tasks of the operational amplifier
The Power Stack Adapter returns analog signals within a range of values from 0 V to 10 V to
the DM10 diagnosis module. Because of this fixed value range, signed signals such as the
actual speed value cannot be represented. Eight AD8674 operational amplifiers boost the
voltage signal (reduced by 5 V) by a factor of 2. As a result of this signal handling, it is also
possible to represent signals in a range of values from -10 V to +10 V.
SINAMICS SM150 6SL3810-7NN38-0AA1
Operating Instructions Rev.201910281406 EXAMPLE
3.5 Description of the components
Description
41