  • Page 1 PSSu H FS SN SD (M12) (-T)(-R) Decentralised system PSSuniversal I/O Operating Manual-1001451-EN-13...
  • Page 2 Preface This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for the user's internal purposes. Suggestions and comments for improving this documenta- tion will be gratefully received.
  • Page 3: Table Of Contents

    ......................Terminal configuration ......................Connecting the module......................Operation ..........................Messages ..........................Display elements ........................8.2.1 MBUS ............................8.2.2 CARD..........................8.2.3 DIAG ............................8.2.4 ST SNp ............................. 8.2.5 FS SNp ............................. Operating Manual PSSu H FS SN SD (M12) (-T)(-R) 1001451-EN-13...
  • Page 4 8.2.6 5V, 24V ............................. 8.2.7 X3: LNK, X3: TRF, X4: LNK, X4: TRF ..................Technical details ........................Safety characteristic data ......................Order reference ........................10.1 Product ............................. 10.2 Accessories ..........................Operating Manual PSSu H FS SN SD (M12) (-T)(-R) 1001451-EN-13...
  • Page 5: Introduction

    CAUTION! This refers to a hazard that can lead to a less serious or minor injury plus material damage, and also provides information on preventive measures that can be taken. Operating Manual PSSu H FS SN SD (M12) (-T)(-R) 1001451-EN-13...
  • Page 6 It also highlights areas within the text that are of particular import- ance. INFORMATION This gives advice on applications and provides information on special fea- tures. Operating Manual PSSu H FS SN SD (M12) (-T)(-R) 1001451-EN-13...
  • Page 7: Overview

    – Plug-in connection terminals (either spring-loaded terminal or screw terminal) Status LEDs T-type: PSSu H FS SN SD (M12)-T: For increased environmental requirements R-type: PSSu H FS SN SD (M12)-R: For railway applications Operating Manual PSSu H FS SN SD (M12) (-T)(-R)
  • Page 8: Front View

    Overview Front view Front view of head modules with an RJ45 female connector Reset Operating Manual PSSu H FS SN SD (M12) (-T)(-R) 1001451-EN-13...
  • Page 9 Front view of head modules with an M12 female connector Legend SafetyNET p interface SafetyNET p interface Labelling strip (see below for details) Status LEDs SD card Reset pushbutton Supply voltage connection (module and periphery supply) Operating Manual PSSu H FS SN SD (M12) (-T)(-R) 1001451-EN-13...
  • Page 10 The labelling strip contains the following information: Order number 312085 Serial number 100017 Hardware version HW 001 2D code: Product information MAC address 0002 4840 3152 2D code: MAC address Operating Manual PSSu H FS SN SD (M12) (-T)(-R) | 10 1001451-EN-13...
  • Page 11: Safety

    The module is suitable for use in safety and non-safety-related applications with SafetyNET p. The modules PSSu H FS SN SD and PSSu H FS SN SD-T may be used as a safety com- ponents in accordance with the Lifts Directive 95/16/EC in accordance with the require- ments of EN 81-1/2:1998+A3:2009, EN 81-20:2015, EN 81-50:2015, EN 81-22:2014 and...
  • Page 12: Warranty And Liability

    In safety-related applications, please comply with the mission time T in the safety-related characteristic data. When decommissioning, please comply with local regulations regarding the disposal of electronic devices (e.g. Electrical and Electronic Equipment Act). Operating Manual PSSu H FS SN SD (M12) (-T)(-R) | 12 1001451-EN-13...
  • Page 13: Function Description

    The module supply does not automatically switch off if values exceed or drop below their limits. However, the "5 V" LED will light and a message will be entered in the diagnostic list. Periphery supply Operating Manual PSSu H FS SN SD (M12) (-T)(-R) | 13 1001451-EN-13...
  • Page 14 However, the "24 V" LED will light and a message will be entered in the dia- gnostic list. Please refer to the derating diagrams. PSSu H FS SN SD: Derating diagram for periphery supply: Temperature T dependent on load current I T (°C)
  • Page 15: Integrated Protection Mechanisms

    Function description PSSu H FS SN SD(-T)(-R): Derating diagram for infeed for module supply: Permitted ambi- ent temperature T dependent on load current I T [°C] I [A] Integrated protection mechanisms The module has the following protection mechanisms: Multi-channel diverse processor section Cyclical self tests Potentially isolated SafetyNET p interface...
  • Page 16: Decentralised Inputs And Outputs

    The SD card can also be sealed to protect it from manipulation, whether accidental or intentional. Sealing the SD card for additional protection: Operating Manual PSSu H FS SN SD (M12) (-T)(-R) | 16 1001451-EN-13...
  • Page 17: Reset Button

    The warm reset and the transfer of the naming data and/or device project are described in the "PSS 4000 System Description". This is also where the general effects on the PSSu system are described in detail. Operating Manual PSSu H FS SN SD (M12) (-T)(-R) | 17 1001451-EN-13...
  • Page 18: Installation

    Push the head module back as far as it will go [2]. Make sure that the locking mechanisms [3] are pushed downwards, connecting the mod- ule firmly to the mounting rail. Operating Manual PSSu H FS SN SD (M12) (-T)(-R) | 18 1001451-EN-13...
  • Page 19 Installation Schematic representation: Operating Manual PSSu H FS SN SD (M12) (-T)(-R) | 19 1001451-EN-13...
  • Page 20: Interface Assignment

    Assignment of the interfaces on head modules with an M12 female connector SafetyNET p Assignment 4-pin M12 female connector 1: TD+ 2: RD+ D-coded 3: TD- 4 RD- 5: Connection to functional earth on the connector hous- Operating Manual PSSu H FS SN SD (M12) (-T)(-R) | 20 1001451-EN-13...
  • Page 21: Wiring

    0 V infeed for module supply Periphery supply Terminal configuration 4-pin female con- 24V: +24 V infeed for peri- nector phery supply 0 V infeed for periphery supply Functional earth Operating Manual PSSu H FS SN SD (M12) (-T)(-R) | 21 1001451-EN-13...
  • Page 22: Connecting The Module

    Common power supply for module supply and periphery supply: Infeed for Module Supply 10 A Infeed for Periphery Supply Connect to the 0 V supply and earth at exactly this point Operating Manual PSSu H FS SN SD (M12) (-T)(-R) | 22 1001451-EN-13...
  • Page 23: Operation

    LEDs on the PSSu H FS SN SD: MBUS SD CARD DIAG X3: LNK X3: TRF ST SNp X4: LNK FS SNp X4: TRF Legend LED on LED flashes LED off Operating Manual PSSu H FS SN SD (M12) (-T)(-R) | 23 1001451-EN-13...
  • Page 24: Mbus

    (e.g. a module has been removed during operation, actual/ registered hardware does not match) Operating state "FS module bus in a STOP condition with error: Major FS error" Operating Manual PSSu H FS SN SD (M12) (-T)(-R) | 24 1001451-EN-13...
  • Page 25: Sd Card

    No device project on the SD card Green-red Naming data and device project on the PSSu system and SD card do not match orange Device identification activated by user Operating Manual PSSu H FS SN SD (M12) (-T)(-R) | 25 1001451-EN-13...
  • Page 26: Diag

    A message of at least "Warning" severity is present for the device (see diagnostic list). Red - green Start of "deliberate operator action" (function of reset button) Operating Manual PSSu H FS SN SD (M12) (-T)(-R) | 26 1001451-EN-13...
  • Page 27: St Snp

    Operating state "ST SafetyNET p RTFN in RUN condition without error" Operating state "ST SafetyNET p RTFN in RUN condition with minor error" Operating state "ST SafetyNET p RTFN in STOP condition with error: Major FS+ST error" Operating Manual PSSu H FS SN SD (M12) (-T)(-R) | 27 1001451-EN-13...
  • Page 28: Fs Snp

    Operating state "FS SafetyNET p RTFN in STOP condition with error: Major FS error" Operating state "FS SafetyNET p RTFN in STOP condition with error: Major FS+ST error Operating Manual PSSu H FS SN SD (M12) (-T)(-R) | 28 1001451-EN-13...
  • Page 29: 5V, 24V

    The "24 V" LED shows the status of the periphery supply. Colour Status Meaning - - - No supply voltage for periphery supply or supply voltage is faulty Green Periphery supply is available on the module bus Operating Manual PSSu H FS SN SD (M12) (-T)(-R) | 29 1001451-EN-13...
  • Page 30: X3: Lnk, X3: Trf, X4: Lnk, X4: Trf

    Network connection is error-free The designation "LNK" stands for "LINK". X3: TRF, X4: TRF Colour Status Meaning No data traffic Yellow Data traffic is error-free The designation "TRF" stands for "TRAFFIC". Operating Manual PSSu H FS SN SD (M12) (-T)(-R) | 30 1001451-EN-13...
  • Page 31: Technical Details

    Voltage tolerance -30 %/+25 % -30 %/+25 % -30 %/+25 % Max. continuous cur- rent that the external power supply must provide 10 A 10 A 10 A Operating Manual PSSu H FS SN SD (M12) (-T)(-R) | 31 1001451-EN-13...
  • Page 32 60068-2-2, EN 60068-2-2, EN 60068-2-30, EN 60068-2-30, EN 60068-2-30, EN 60068-2-78 60068-2-78 60068-2-78 Ambient temperature Temperature range 0 - 60 °C -40 - 70 °C -40 - 70 °C Operating Manual PSSu H FS SN SD (M12) (-T)(-R) | 32 1001451-EN-13...
  • Page 33 Periphery supply and between module supply module supply module supply Type of potential isolation Functional insulation Functional insulation Functional insulation Rated surge voltage 2500 V 2500 V 2500 V Operating Manual PSSu H FS SN SD (M12) (-T)(-R) | 33 1001451-EN-13...
  • Page 34 CE, TÜV CE, TÜV Application range Standard/failsafe Standard/failsafe System sections 315085 315086 ST resource FS resource ST module bus FS module bus ST SNp interface FS SNp interface Operating Manual PSSu H FS SN SD (M12) (-T)(-R) | 34 1001451-EN-13...
  • Page 35 Buffer time 10 days 10 days Working memory (RAM) 64 MB 64 MB Removable data medium 315085 315086 Type SD card SD card SafetyNET p interface 315085 315086 Number Operating Manual PSSu H FS SN SD (M12) (-T)(-R) | 35 1001451-EN-13...
  • Page 36 0,572 g RMS 0,572 g RMS In accordance with the standard EN 50125-3 EN 50125-3 Frequency 5 - 2.000 Hz 5 - 2.000 Hz Acceleration 0,23g RMS 0,23g RMS Operating Manual PSSu H FS SN SD (M12) (-T)(-R) | 36 1001451-EN-13...
  • Page 37 TWIN crimp con- nectors 0,2 - 1,5 mm², 24 - 16 AWG 0,2 - 1,5 mm², 24 - 16 AWG Torque setting with screw terminals 0,5 Nm 0,5 Nm Operating Manual PSSu H FS SN SD (M12) (-T)(-R) | 37 1001451-EN-13...
  • Page 38: Safety Characteristic Data

    A safety function's SIL/PL values are not identical to the SIL/PL values of the units that are used and may be different. We recommend that you use the PAScal software tool to calculate the safety function's SIL/PL values. Operating Manual PSSu H FS SN SD (M12) (-T)(-R) | 38 1001451-EN-13...
  • Page 39: Order Reference

    Terminals Product type Features Order no. PSSu A Con 1/4 S 2 x screw terminals 313 110 PSSu A Con 2/8 C 2 x spring-loaded terminals 313 111 Operating Manual PSSu H FS SN SD (M12) (-T)(-R) | 39 1001451-EN-13...
  • Page 40 Front cover Support Technical support is available from Pilz round the clock. Americas Australia Scandinavia Brazil +61 3 95600621 +45 74436332 +55 11 97569-2804 Spain Canada Europe +34 938497433 +1 888-315-PILZ (315-7459) Austria Switzerland Mexico +43 1 7986263-0 +41 62 88979-30...

Table of Contents