  • Page 1 PSSu H S PN Decentralised system PSSuniversal I/O Operating Manual-22103-EN-05...
  • Page 2 Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions and comments for improving this documentation will be gratefully received.
  • Page 3: Table Of Contents

    Section 5 Installation General installation guidelines Dimensions Installing the head module Section 6 Interfaces Interface configuration 6.1.1 Connection to PROFINET Section 7 Operation Display elements Section 8 Technical Details Section 9 Order reference Operating Manual PSSu H S PN 22103-EN-05...
  • Page 4: Operating Manual Pssu H S Pn

    Introduction Introduction Validity of documentation This documentation is valid for the PSSu H S PN module. It is valid until new documenta- tion is published. Please also refer to the following documents: PSSuniversal System Description PSSuniversal Installation Manual This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
  • Page 5 It also highlights areas within the text that are of particular import- ance. INFORMATION This gives advice on applications and provides information on special fea- tures. Operating Manual PSSu H S PN 22103-EN-05...
  • Page 6: Overview

    PROFIenergy in conjunction with all digital output modules plus the following input mod- ules: – PSSu E S 4DI-D – PSSu E S PD-D Electronic modules that can be used for input/output: – All standard modules (PSSu E S...) Operating Manual PSSu H S PN 22103-EN-05...
  • Page 7: Front View

    4: Labelling strip with: – Order number – Serial number – Hardware version number 5: Field for 2D code 6: LEDs for diagnostics on the PROFINET connection 7: Description of head module 8: Chip card slot Operating Manual PSSu H S PN 22103-EN-05...
  • Page 8: Safety

    Updating the firmware can also expand the module's functionality. INFORMATION The module's actual firmware version can only be established using the Firmware Manager on the PSSuniversal Assistant. Operating Manual PSSu H S PN 22103-EN-05...
  • Page 9: Safety Regulations

    In safety-related applications, please comply with the mission time T in the safety-re- lated characteristic data. When decommissioning, please comply with local regulations regarding the disposal of electronic devices (e.g. Electrical and Electronic Equipment Act). Operating Manual PSSu H S PN 22103-EN-05...
  • Page 10: Function Description

    Using the PROFINET project chip card – If the head module already contains a project, you will need to delete this project first (see below). Operating Manual PSSu H S PN 22103-EN-05...
  • Page 11: Profinet

    The PROFINET interface enables standard data to be exchanged with a higher level control system. All the project data is stored in the head module. The project data can also be stored on a chip card. Operating Manual PSSu H S PN 22103-EN-05...
  • Page 12: Installation

    Electrostatic discharge can damage components. Ensure against discharge before touching the product, e.g. by touching an earthed, conductive sur- face or by wearing an earthed armband. Dimensions 21,6 mm (0.85") 72,6 mm 75,2 mm (2.858") (2.96") Operating Manual PSSu H S PN 22103-EN-05...
  • Page 13: Installing The Head Module

    Install an end bracket to the left of the head module or leave enough space for one. Slot the groove on the head module on to the mounting rail from below [1]. Push the head module back [2] until you hear it lock into position. Schematic representation: Operating Manual PSSu H S PN 22103-EN-05...
  • Page 14: Interfaces

    (e.g. through shock, vibration). Such measures include fixed routing und strain relief, for example. We also recommend the use of an angled RJ45 connector. Operating Manual PSSu H S PN 22103-EN-05...
  • Page 15: Operation

    Meaning gnostics "SF" status "BF" status 312 040 (red) (red) 0000000 HW 000 No supply voltage or fault-free operation No Ethernet connection No PROFINET connection Diagnostic entry present PSSu H S PN CHIP Operating Manual PSSu H S PN 22103-EN-05...
  • Page 16 0000000 No supply voltage HW 000 Green Supply voltage present Green Device is in PROFIenergy mode Error in the configuration or hardware registry PSSu H S PN Head module error Forcing CHIP ange Operating Manual PSSu H S PN 22103-EN-05...
  • Page 17 Colour 312 040 0000000 Li 1 Green Connection X1 HW 000 Li 2 Green Connection X2 Tr 1 Yellow Data transfer X1 Tr 2 Yellow Data transfer X2 PSSu H S PN CHIP Operating Manual PSSu H S PN 22103-EN-05...
  • Page 18: Technical Details

    Not permitted EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-6-2, EN 61000-6-4 Vibration In accordance with the standard EN 60068-2-6 Frequency 10,0 - 150,0 Hz Amplitude 0,35 mm Acceleration Operating Manual PSSu H S PN 22103-EN-05...
  • Page 19 Mounting area (e.g. control cabinet) IP54 Housing IP20 Mechanical data Material Bottom Front Dimensions Height 128,4 mm Width 75,2 mm 79,4 mm Depth 170 g Weight Where standards are undated, the 2015-03 latest editions shall apply. Operating Manual PSSu H S PN 22103-EN-05...
  • Page 20: Order Reference

    Order reference Order reference Product type Features Order No. PSSu H S PN Head module with PROFINET interface, base type 312 041 Operating Manual PSSu H S PN 22103-EN-05...
  • Page 21 Front cover Support Technical support is available from Pilz round the clock. Americas Australia Scandinavia Brazil +61 3 95446300 +45 74436332 +55 11 97569-2804 Spain Canada Europe +34 938497433 +1 888-315-PILZ (315-7459) Austria Switzerland +41 62 88979-30 Mexico +43 1 7986263-0...