  • Page 2 Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions and comments for improving this documentation will be gratefully received.
  • Page 3: Table Of Contents

    Changing an electronic module during operation Section 6 Wiring General wiring guidelines 6.1.1 Mechanical connection of the base modules Terminal configuration Connecting the module Section 7 Operation Messages Display elements 7.2.1 Anzeigeelemente zur Moduldiagnose Operating Manual PSSu E F PS(-T) 21292-EN-06...
  • Page 4 Contents 7.2.2 Display elements for the status of the module supply and periphery supply 30 Status byte Section 8 Technical details Section 9 Order reference Product Accessories Operating Manual PSSu E F PS(-T) 21292-EN-06...
  • Page 5: Operating Manual Pssu E F Ps(-T)

    Introduction Validity of documentation This documentation is valid for the products PSSu E F PS and PSSu E F PS-T. It is valid until new documentation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
  • Page 6 Introduction INFORMATION This gives advice on applications and provides information on special fea- tures. Operating Manual PSSu E F PS(-T) 21292-EN-06...
  • Page 7: Overview

    Separate infeed for module supply Infeed for C-rail supply LEDs for: – Module supply – Periphery supply – Module error Application range depends on the base module T-type: PSSu E F PS-T: for increased environmental requirements Operating Manual PSSu E F PS(-T) 21292-EN-06...
  • Page 8: Front View

    2D code 3: Labelling strip for the terminal configuration on the base module 4: Name of electronic module 5: Connection level 1 6: Connection level 2 7: Connection level 3 8: Connection level 4 Operating Manual PSSu E F PS(-T) 21292-EN-06...
  • Page 9 10: Round connection holes (connection levels 1, 2, 3 and 4) for connecting the signal lines 11: Mounting slot for colour marker to label the connection level (connection levels 1, 2, 3 and 4) Operating Manual PSSu E F PS(-T) 21292-EN-06...
  • Page 10: Safety

    Supply module to refresh the module supply and periphery supply Supply module to form supply groups The module PSSu E F PS-T is suitable for use where there are increased environmental re- quirements (see Technical Details). Intended use includes making the electrical installation EMC-compliant. Please refer to the guidelines stated in the "PSSuniversal Installation Manual".
  • Page 11: Safety Regulations

    In safety-related applications, please comply with the mission time T in the safety-re- lated characteristic data. When decommissioning, please comply with local regulations regarding the disposal of electronic devices (e.g. Electrical and Electronic Equipment Act). Operating Manual PSSu E F PS(-T) 21292-EN-06...
  • Page 12: Function Description

    Supply groups to be formed The relevant base module interrupts the connection to the incoming (left-hand) peri- phery supply and C-rail on the module bus. Each supply group requires its own supply module. Operating Manual PSSu E F PS(-T) 21292-EN-06...
  • Page 13: Current Load Capacity

    If the current load is higher, the C-rail must use a different supply to prevent overload. Please refer to the derating diagram. PSSu E F PS: Derating diagram for periphery supply and C-rail: Temperature T dependent on load current I T (°C)
  • Page 14 Function description PSSu E F PS-T: Derating diagram for infeed for periphery supply: Permitted ambient tem- perature T dependent on load current I T [°C] 10 I [A] PSSu E F PS-T: Derating diagram for infeed for module supply: Permitted ambient temper- ature T dependent on load current I T [°C]...
  • Page 15: Integrated Protection Mechanisms

    The configuration is made in the PSSuniversal Configurator in the PSS WIN-PRO system software: Read access through the standard bus system: “R” configuration Further information on configuration is available in the PSSuniversal Configurator's online help. Operating Manual PSSu E F PS(-T) 21292-EN-06...
  • Page 16: Addresses In The Process Image

    I/O-Group (SafetyBUS p) is set to zero. The I/O-Group switches to a STOP condition. An error telegram is then triggered on Safety- BUS p and the error is entered in the PSSuniversal error stack. Operating Manual PSSu E F PS(-T) 21292-EN-06...
  • Page 17: Installation

    5.1.1 Dimensions Base modules with four connection levels: 12,6 mm 8,1 mm 52,1 mm (0.496") (0.319") (2.051") 12,6 mm 72,6 mm (0.496") (2.858") Operating Manual PSSu E F PS(-T) 21292-EN-06...
  • Page 18: Installing The Base Module

    Push the base module back [2] until you hear it lock into position. On the mounting rail, slide the base module to the left until you hear the two lateral mounting hooks on the adjacent module lock into position [3]. Schematic representation: Operating Manual PSSu E F PS(-T) 21292-EN-06...
  • Page 19: Inserting And Removing An Electronic Module

    This is how the base module is coded. The mechanics of the electronic modules are designed for 50 plug in/out cycles. Operating Manual PSSu E F PS(-T) 21292-EN-06...
  • Page 20: Inserting An Electronic Module

    Installation 5.3.1 Inserting an electronic module Procedure: The electronic module must audibly lock into position [1]. Mark the electronic module using the labelling strips [2]. Schematic representation: Operating Manual PSSu E F PS(-T) 21292-EN-06...
  • Page 21: Removing An Electronic Module

    – The substitute values are used for the modules' FS outputs, with Valid Bits = FALSE. CAUTION! Sparking can cause interference and errors! Only change the module when the load is switched off! Operating Manual PSSu E F PS(-T) 21292-EN-06...
  • Page 22: Wiring

    Insert the stripped cable into the round fixing hole [2], as far as it will go. – Tighten up the screw on the screw terminal. – Check that the cable is firmly seated. Operating Manual PSSu E F PS(-T) 21292-EN-06...
  • Page 23 Inputs/outputs on the counter modules: 1.5 mm (AWG16) – Analogue inputs/outputs: 1.5 mm (AWG16) – Communication cables: 1.5 mm (AWG16) – Test pulse outputs: 1.5 mm (AWG16) – Power supply: 2.5 mm (AWG12) – Functional earth: 2.5 mm (AWG12) Operating Manual PSSu E F PS(-T) 21292-EN-06...
  • Page 24: Terminal Configuration

    (12-22 linked within the base module) 13 -23: +24 V periphery sup- ply, interrupted to the left (13-23 linked within the base module) 14-24 C-rail supply, interrupted to the left (14-24 linked within the base module) Operating Manual PSSu E F PS(-T) 21292-EN-06...
  • Page 25 – To provide subsequent modules with the module supply, periphery supply and C- rail supply With these base modules the supply module cannot be used as the first module after the head module. Operating Manual PSSu E F PS(-T) 21292-EN-06...
  • Page 26 (12-22 linked within the base module) 13 -23: +24 V periphery sup- ply, interrupted to the left (13-23 linked within the base module) 14-24 C-rail supply, interrupted to the left (14-24 linked within the base module) Operating Manual PSSu E F PS(-T) 21292-EN-06...
  • Page 27: Connecting The Module

    - PSSu BS 1/8C(-T) - PSSu BS-R 1/8S(-T) - PSSu BS-R 1/8C(-T) Connect to the C-rail Supply Connect to the 0 V supply and earth at a single point Module Supply Periphery Supply Operating Manual PSSu E F PS(-T) 21292-EN-06...
  • Page 28 - PSSu BS 1/8S(-T) - PSSu BS 1/8C(-T) oder - PSSu BS-R 1/8S(-T) - PSSu BS-R 1/8C(-T) Connect to the C-rail Supply Connect to the 0 V supply and earth at a single point Operating Manual PSSu E F PS(-T) 21292-EN-06...
  • Page 29: Operation

    Legend LED on LED flashes LED off 7.2.1 Anzeigeelemente zur Moduldiagnose The module has an LED for displaying module errors ("Err" LED). Meaning Name Colour Status - - - No error Module error Operating Manual PSSu E F PS(-T) 21292-EN-06...
  • Page 30: Display Elements For The Status Of The Module Supply And Periphery Supply

    24 V - - - Error in the supply voltage for periphery supply No supply voltage for periphery sup- green Supply voltage for periphery supply is er- ror-free Operating Manual PSSu E F PS(-T) 21292-EN-06...
  • Page 31: Status Byte

    General error in the PSSu ST section No error on the FS modules At least one FS module is registering an error No error on the ST modules At least one ST module is registering an error Reserved Operating Manual PSSu E F PS(-T) 21292-EN-06...
  • Page 32: Technical Details

    -30 %/+25 % -30 %/+25 % 10 A 10 A Current load capacity at UB Rated surge voltage 3050 V 3050 V Potential isolation between module supply and periphery supply 3050 V 3050 V Operating Manual PSSu E F PS(-T) 21292-EN-06...
  • Page 33 10 - 150 Hz 10 - 1000 Hz 0,35 mm 0,35 mm Amplitude Acceleration Broadband noise EN 60068-2-64 In accordance with the standard – Frequency – 5 - 500 Hz 1,9grms Acceleration – Operating Manual PSSu E F PS(-T) 21292-EN-06...
  • Page 34 76 mm Height Width 12,6 mm 12,6 mm Depth 60,2 mm 60,2 mm Weight 39 g 40 g Mechanical coding Type Colour Yellow Yellow Where standards are undated, the 2015-03 latest editions shall apply. Operating Manual PSSu E F PS(-T) 21292-EN-06...
  • Page 35: Order Reference

    Base module with cage clamp terminals, for use only to refresh 312 653 the voltage and form supply groups PSSu BS-R 1/8 C- Base module with cage clamp terminals, for use only to refresh 314 653 the voltage and form supply groups, T-type Operating Manual PSSu E F PS(-T) 21292-EN-06...
  • Page 36 Back cover Support Technical support is available from Pilz round the clock. Americas Australia Scandinavia Brazil +61 3 95600621 +45 74436332 +55 11 97569-2804 Spain Canada Europe +34 938497433 +1 888-315-PILZ (315-7459) Austria Switzerland +41 62 88979-30 Mexico +43 1 7986263-0...