DISPLAY
RATE
DATA
bAUd
1200
TriG
0
UniT
FT
dLoG
oFF
1)
Definition of Data Menu Key:
Depressing this key displays selected Data Menu features in RATE display.
EXAMPLE: RATE display will display options by name and DATA will display
default setting.
Depressing this key after selecting DATA MENU toggles up through desired
features.
EXAMPLE: "Prn" "bEGn, "ALrn""on", "diSP""on", etc....
Depressing this key after selecting DATA MENU toggles down through desired
features.
EXAMPLE: "Prn" "bEGn, "DLoG""oFF", "UniT""FT", etc....
2)
CONSOLE DATA PRINTOUT
A)
RATE display will show "Prn". DATA display will show "bEGn" (Print Field
Begin).
1)
To Print Field Begin, depress key labelled
B)
RATE display will now show "Prn" and DATA display will show "End" (Print
Field End).
1)
To Print Field End, depress key labelled
2)
While "End" is displayed, if Field Begin is required, depress key
labelled
C)
Momentarily depress
FEATURE and DESCRIPTION
BAUD RATE
Used in GPS mode and data logging mode. Selectable between
1200 or 9600 baud (Serial interface console only).
DATA LOGGER TRIGGER VALUE
Used in data logging mode. The trigger determines how often
actual rate data string (See Appendix 9 for data communi-
cation string formats) is sent to the serial port.
trigger may be either feet [meters] or seconds (Serial
interface console only).
DATA LOGGER TRIGGER UNITS
Used in data logging mode.
between feet [meters] or seconds (Serial interface console
only).
DATA LOGGER ON/OFF
Turns data logger ON or OFF (Serial interface console only).
to toggle DATA display to "BEGn".
to advance to AUDIBLE ALARM ON/OFF.
22
The trigger unit is selectable
The