APPENDIX - A
High Integrity Probes (stainless steel)
The probe is supplied in two parts, the head and the tip. The tip should be screwed onto the head aligning the slot
in the top of the tip with the hole in the screwed shaft of the head.
Locate the pin provided into the slot/hole and secure with the lock nut.
Using the measurement from the old probe, cut the new probe to length and de-burr. Ensure both measurements
are taken from the underside of the hex. nut on the probe head.
Ensure measurements are
taken from the underside of
the hex. nut on the probe
head.