switch tables 3-2 through 3-4. See Section 5 Service and
Maintenance for board access procedures. Once patterns
are chosen for each of the program inputs, then the pro-
gram inputs are assigned to a slide switch position.
The default program inputs assigned to a slide
switch position, along with the default pattern for each
program input are as follows:
•
Slide switch position #1 – P1, Rear Flashing
•
Slide switch position #2 – P2, Rotate 90 FPM
•
Slide switch position #3 – P2, Rotate 90 FPM
To assign a different Smart Pod program input to a
slide switch position perform the following:
A.
Disconnect power to the lightbar. If the cover
is removed, this can be accomplished by removing the
10GA RED power wire from the relay.
B.
Apply 12VDC to the WHT/YEL and WHT/
BLK control wires.
C.
Apply power to the lightbar (reconnect the
RED 10GA power wire.)
D.
The right upper LED module in POD #4 will
light indicating the bar is in Smart Pod programming
mode.
Table 3-2
P1
Rear
Oscillating Oscillating
Switches Flashing* Rear
(S2)
P1A
OFF
ON
P1B
OFF
OFF
P1C
OFF
OFF
Table 3-3
P2
Rotate Rotate Rotate Oscillating
Switches 90
120
(S2)
FPM*
FPM
P2A
OFF
ON
P2B
OFF
OFF
P2C
OFF
OFF
Table 3-4
P3
Oscillating
Switches Intersection*
(S1)
P3C
OFF
P3B
OFF
P3A
OFF
* Factory Setting
Oscillating Rotate
Intersection Front
OFF
ON
ON
ON
OFF
OFF
Oscillating Front
175
Intersection Front
FPM
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
ON
Oscillating
Rotate
Rotate Rotate
Front
175
120
FPM
FPM
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
ON
E.
Move the slide switch to the desired position.
The following will be displayed for each slide switch po-
sition:
1.
Slide Switch #1 – Front LED module
POD #1 and the Smart Pods will operate according to
the stored program input.
2.
Slide Switch #2 – Front LED module
POD #1,the upper LED module POD #1 and the Smart
Pods will operate according to the stored program input.
3.
Slide Switch #3 - Front LED module
POD #1,the upper LED module POD #1,rear LED mod-
ule POD #1 and the Smart Pods will operate according
to the stored program input.
F.
Remove 12VDC from the WHT/BLK control
wire. Momentarily re-apply 12VDC to the WHT/BLK
control wire and the Smart Pods will advance to the
next program input. Each time 12VDC is momentarily
applied to the WHT/BLK control wire the program num-
ber will advance. When the last available program num-
ber is reached the next operation will select the first
available program, which is OFF.
G.
If programs assigned to the other slide switch
positions are to be changed, move the slide switch to the
desired position and repeat the above steps.
Rotate Rotate
90
120
175
FPM
FPM
FPM
OFF
ON
OFF
OFF
OFF
ON
ON
ON
ON
Oscillating
Flashing
Rear
ON
OFF
OFF
ON
ON
ON
Front
Oscillating Rear
90
Flashing Rear
FPM
ON
ON
ON
OFF
OFF
ON
OFF
ON
OFF
-5-
Front
Flashing
ON
ON
ON
Rear
Flashing
ON
ON
ON
Flashing
ON
ON
ON
Need help?