8 Troubleshooting
For the common faults, inspection methods and corrective measures see
Table 8-1.
Table 8-1
PDF 文件使用 "pdfFactory Pro" 试用版本创建
调高器说明书
Inspection items
Fault
Powered on or not?
the voltage of power supply
is normal or not
motor is overloaded or not
No display
Check the power supply
Upper limit
The upper limit value is
alarm
exceeded
Lower limit
The lower limit value is
alarm
exceeded
the work piece is grounded
Instable signal
properly or not
Inaccurate
Operating environment
height
changed
Speed reduction zone value is
Vibrate wil dly
too small
Too slow in
Speed reduction zone value is
tracking
too big
Slight
Dead zone value is too small
vibration
Too low
Dead zone value is too big
accuracy
www.fine print.com.cn
Corrective measures
Power it on
Check the power
supply
Reduce load
Power on
Check the upper limit
switch
Check the lower limit
switch
Ground it firmly
Run "one-keystoke
height calibration"
Increase the speed
reduction zone value d
Reduce the speed
reduction zone value d
Increase the dead zone
value E
Reduce the dead zone
value E
38
Need help?
Do you have a question about the SH-HC30 and is the answer not in the manual?
Questions and answers