MicroStep SH-HC30 User Manual page 42

Height controller for flame / plasma cutting torch
Hide thumbs Also See for SH-HC30:
Table of Contents

Advertisement

PDF 文件使用 "pdfFactory Pro" 试用版本创建
调高器说明书
When the last 3 digits are
it indicat es anupper-limit ala rm.
When the last 3 digit s are
indicates a lower-limit alarm.
When the last 4 digits are
po sit ion is reached.
When the last 4 digits are
po sit ion is reached.
Param eter editing mode: The first digit indicat es the parameter name;
the second one indicates the equal sign
indicat e the pa rameter value( In capacitance mode, it is a decimal
accurat e to 0.1 mm; in arc voltage mode, it is a integer in V. The first
digit is particularly described as follows:
H: the upper limit value. When the height of cutt ing torch
is
larger than t his value, an upper-limit ala rm will be
triggered.
In this case, the cutting torch can only move down.
L: lower limit value. When the height is lower than this value,
it is a lower- limit alarm will be activated. In this case, the
cutting torch can only move up.
A: the set value of height; in automatic mode, this value
is
used as the given value fo r automatic height adjustment.
E: Dead zone value (see 7.1).
D: Speed regulating zone value (see 7.1).
C: select ion of detector mode (see 7.1).
b: No board descending parameter value (see 7.1)
www.fine print.com.cn
and the height value flashes,
and the height value flashes, it
, it indicates the upper limit
, it indicates t he lower limit
; t he last 3 flashing digits