GCC Technologies Puma Series Maintenance Manual page 27

Cutting plotters
Table of Contents

Advertisement

3. Remove the Lever and Lever Assembly
Step1. Loosen the E-snap Ring on Square Bar and remove Switch Cam.
Step2. Shift the Lever Assembly (Fig 1-3) to the right (view from rear) to
dismount from the machine.
Step3. Loosen the screws (Fig 1-3) beneath Lever to remove the Lever.
**If you just need to replace Lever, please refer to Step 3 to install the Lever Assembly, please
make sure Switch Cam and Lever Switch are well positioned, then follow by
.
Step 3a.
Lever is down.
Step 3b.
Make sure the Switch Cam is holding the switch down.
Step 3c.
Fix the E-snap Ring back.
4. Remove the Lever Switch
Remove the screws (Fig 1-3) on the switch while the Lever in up position.
Y-Motor
Switch & fixing screws
Switch Cam
E-snap Ring
Fig 1-3
Lever Screw
27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Puma iii 60Expert pro series

Table of Contents