MATERIAL TEMPERATURE indicator
This is the current mixed material temperature at the outlet of mixer shroud.
Material temperature status indicator.
This gives the status of the current mixed material temperature.
TEMP NOT READY: The material is currently below specified temperature limits.
MATERIAL TEMP OK: The current material temperature is at specified limits.
MATERIAL TEMP HIGH: The material is currently above specified temperature limits.
NOTE: When the material is above a specified temperature, a material overheat alarm will
be enabled.
SILENCE ALARM button: This button will silence the material overheat alarm.
ADJUST TEMPERATURE
INCR TEMP button (Increment Temperature)
This button will increment all the temperature settings by 1C° every time the button is pressed.
DECR TEMP button (Decrement Temperature)
This button will decrease all the temperature settings by 1C° every time the button is pressed
For more information on the material temperature set points,
see the CALIBATION screen section of this manual.
NOTE: