Technical Specifications - Parker PNEUDRI domnick hunter MAXI PLUS MPXS Series Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 7
2. TECHNICAL SPECIFICATION
A)
GENERAL
Type:
Model:
Outlet Dewpoint:
Air Quality:
(dirt/water/oil):
Maximum Operating Pressure:
Minimum Operating Pressure:
Maximum Inlet Temperature:
Minimum Inlet Temperature:
Regeneration:
Nominal pressure drop
across desiccant bed:
Standard Electrical Supply:
Controls:
Controller:
Noise Level (Average):
Media:
Material:
Construction:
Pre filtration:
After filtration:
Pressure Swing Adsorption (PSA)
MPXE - electronic with integrated display
High tensile extruded aluminium coated with Alocrom anti-corrosion
protection and paint finished with an abrasion resistant dry powder epoxy
coating.
PNEUDRI is constructed from extruded aluminium sections connected
together by high tensile bolts i.e. desiccant filled columns are contained
between an upper and lower manifold. The configuration varies between the
heatless and heat regenerative models as shown in figures 1 & 2
7
Heatless
MPXE/MPXS
-40°C (-40°F)
-70°C (-100°F) - optional
ISO 8573.1 Class 1.2.1
Class 1.1.1 optional
13.0 bar g (189 psi g)
4 bar g (58 psi g)
50°C (122°F)
5°C (41°F)
[Air Purge Principle]
140 m bar (2 psi)
115/230V/1ph/50Hz/60Hz
Control equipment 24V ac.
MPXS - electronic
<85db (A)
Desiccant
Grade AO/AA OIL-X filters
Grade AR OIL-X filter

Hide quick links: