Job Aid
The following tables show the environmental requirements for the Ethernet Routing Switch
5500 and 5600.
Table 8: Job aid: Ethernet Routing Switch 5500 Series environmental requirements
Ambient Temperature
Storage Temperature
Operating Relative
Humidity
Storage Relative
Humidity
Maximum Operating
Altitude
Storage Altitude
58
Avaya Ethernet Routing Switch 5000 Series Installation
Avaya Ethernet
Avaya Ethernet
Routing Switch
Routing Switch
5510
Between 32 and
Between 32 and
113 degrees
104 degrees
Fahrenheit (0 and
Fahrenheit (0 and
45 degrees
40 degrees
Celsius).
Celsius) for
continuous
operation. This
operational
temperature can be
extended to 131
degrees
Fahrenheit (55
degrees Celsius)
for short time
operation.
Between -40 and
Between -40 and
185 degrees
185 degrees
Fahrenheit (-40
Fahrenheit (-40
and 85 degrees
and 85 degrees
Celsius).
Celsius).
Between 5 and
Between 10 and
85% non-
90% non-
condensing.
condensing.
Between 10 and
Between 10 and
95% non-
95% non-
condensing.
condensing.
10,000 feet (3048
10,000 feet (3048
meters) above sea
meters) above sea
level.
level.
Between -1,000
Between -1,000
and 10,000 feet
and 10,000 feet
(-304.8 and 3048
(-304.8 and 3048
meters) above sea
meters) above sea
level.
level.
Avaya Ethernet
Routing Switch
5520
5530
Between 32 and 122
degrees Fahrenheit
(0 and 50 degrees
Celsius) for
continuous
operation. This
operational
temperature can be
extended to 14 to
140 degrees
Fahrenheit (-10 to
60 degrees Celsius)
for short time
operation.
Between -40 and
185 degrees
Fahrenheit (-40 and
85 degrees
Celsius).
Between 10 and
90% non-
condensing.
Between 10 and
95% non-
condensing.
15,000 feet (4572
meters) above sea
level.
Between -1,000 and
40,000 feet (-340.8
and 12,192 meters)
above sea level.