Chapter 2 Install Cards and Fiber-Optic Cable
During this procedure, wear grounding wrist straps to avoid ESD damage to the card. Do not directly
Warning
touch the backplane with your hand or any metal tool, or you could shock yourself. Statement 94
Class I (21 CFR 1040.10 and 1040.11) and Class 1M (IEC 60825-1 2001-01) laser products. Statement 291
Warning
Warning
Invisible laser radiation may be emitted from the end of the unterminated fiber cable or connector. Do
not view directly with optical instruments. Viewing the laser output with certain optical instruments
(for example, eye loupes, magnifiers, and microscopes) within a distance of 100 mm may pose an eye
hazard. Statement 1056
Always use the supplied ESD wristband when working with a powered ONS 15454 SDH. Plug the
Caution
wristband cable into the ESD jack located on the lower-right outside edge of the shelf assembly.
If protective clips are installed on the backplane connectors of the cards, remove the clips before
Note
installing the cards.
High-performance devices on this card can get hot during operation. To remove the card, hold it by
Warning
the faceplate and bottom edge. Allow the card to cool before touching any other part of it or before
placing it in an antistatic bag. Statement 201
Step 1
If you installed XC-VXL-2.5G cards, review
If you installed XC-VXL-10G or XC-VXC-10G cards, review
card/slot compatibility.
Open the card latches/ejectors.
Step 2
Use the latches/ejectors to firmly slide the card along the guide rails until the card plugs into the
Step 3
receptacle at the back of the slot.
Verify that the card is inserted correctly and close the latches/ejectors on the card.
Step 4
Note
Note
Verify the LED activity:
Step 5
The red FAIL LED turns on for 20 to 30 seconds. The ACT LED is amber for 3 to 5 seconds.
The red FAIL LED blinks for up to 2 minutes.
The FAIL and ACT LEDs blink once and turn off for 1 to 5 seconds.
78-18118-01
It is possible to close the latches/ejectors when the card is not completely plugged into the
backplane. Ensure that you cannot insert the card any further.
If you install the wrong card in a slot, complete the
procedure on page 2-21
and install the correct card.
NTP- D286 Install the FC_MR-4 Cards
Table 2-1 on page 2-3
to determine card/slot compatibility.
Table 2-2 on page 2-5
"NTP-D227 Remove and Replace a Card"
Cisco ONS 15454 SDH Procedure Guide, R8.5
to determine
2-13