Remote Los And Ais Response; Oct55 Test Pattern With Ami Line Code; H2Tu-R Los And Ais Response Priorities - ADC HiGain H2TU-C-388 User Manual

Adc h2tu-c-388 list 1 line unit user manual
Hide thumbs Also See for HiGain H2TU-C-388:
Table of Contents

Advertisement

Testing

Remote LOS and AIS Response

Figure 25
shows the different ways the H2TU-R can respond to the network, depending on the configuration of
the TLOS, NLBP, RDA, and ALMP configuration options described in
page
18.
OCT55 T
P
EST
The OCT55 test pattern can be used in unframed mode to stress the system and verify data integrity. In an SF or
ESF framing mode, excessive zero anomalies may occur, which causes the H2TU-C to report ES, SES and UAS
errors according to ANSI T1.231-1997.
38
Figure 25. H2TU-R LOS and AIS Response Priorities
AMI L
ATTERN WITH
Table 5 on page 17
C
INE
ODE
June 6, 2000
152-388-100-02, Issue 2
and
Table 6 on
H2TU-C-388 List 1