Front-Panel Display Messages - ADC HiGain H2TU-C-388 User Manual

Adc h2tu-c-388 list 1 line unit user manual
Hide thumbs Also See for HiGain H2TU-C-388:
Table of Contents

Advertisement

152-388-100-02, Issue 2
Table 2
lists the front-panel display messages. The four-character display reports the code of an alarm, loopback,
or diagnostic message and, in some cases, is followed by a second four-character message that modifies the first
message with a value or current configuration setting.
Message
Full Name
SYSTEM ALARM MESSAGES
ACO
Alarm Cutoff
ALRM
Alarm Condition Exists
DBER
DS1 Bit Error Rate
HBER
HDSL2 Block Error Rate
LA
Loop Attenuation
LAIS
Local Alarm Indication Signal
LLOS
Local Loss of Signal
LOSW
Loss of Sync Word
LRAI
Line RAI
MAL
Margin Alarm
PWR FEED GND
Ground
PWR FEED OPEN
Open
PWR FEED SHRT
Short
PRMF
Performance Report Messaging -
Far End
PRMN
Performance Report Messaging -
Near End
RAIS
Remote Alarm Indication Signal
RLOS
Remote Loss of Signal
RRAI
Remote RAI
TUC
Transmission Unit Central Office
TUR
Transmission Unit Remote End
LOOPBACK MESSAGES
CLOC
Customer Local Loopback
COLB
Central Office Loopback
CREM
Customer Remote Loopback
NLOC
Network Local Loopback
NREM
Network Remote Loopback
RULB
Remote Unit Loopback
H2TU-C-388 List 1
Table 2. Front-Panel Display Messages
Description
A system alarm has occurred and has been retired to an ACO condition
by pressing the SEL button on the H2TU-C front panel.
A system alarm condition is in effect.
A system DS1 BER alarm is in effect and remains in effect until cleared.
A system HDSL2 Block Error Rate alarm is in effect.
Indicates that the attenuation on the HDSL2 loop has exceeded the
maximum threshold value.
Indicates an AIS (all ones) pattern is being transmitted from the local
DS1 output port.
Indicates that no signal is detected at the DSX-1 input to the H2TU-C.
Causes a system alarm.
Indicates that the HDSL2 loop has lost synchronization.
Indicates an RAI alarm (yellow) from the CPE with an error-free signal
from the line unit or network.
The margin on HDSL2 loop has dropped below the threshold (0 to 15
dB) as set by the operator.
The HDSL2 loop is grounded.
Indicates a line power open condition.
Indicates a short between the Tip and Ring of the HDSL2 pair.
H2TU-R PRM-FE BER threshold has been exceeded.
H2TU-R PRM-NE BER threshold has been exceeded.
Indicates an AIS (all ones) pattern is being transmitted from the remote
DS1 output port.
Indicates that no signal is detected at the DS1 input to the H2TU-R.
Causes a system alarm.
Indicates an RAI alarm (yellow) from the CPE with errors from the line
unit or network.
Accompanies the HBER, MAL, and LA alarm and indicates that the alarm
has occurred at the H2TU-C central office unit.
Accompanies the HBER, MAL, and LA alarm and indicates that the alarm
has occurred at the H2TU-R remote unit.
Signal from customer is looped back to the customer at the H2TU-R.
Dual loopback at the H2TU-C.
Signal from customer is looped back to the customer at the H2TU-C.
DSX-1 signal is looped back to the network at the H2TU-C.
DSX-1 signal is looped back to the network at the H2TU-R.
Dual loopback at the H2TU-R.
June 6, 2000
Front Panel
Continued
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

150-2406-01Higain hdsl2H2tu-c-231

Table of Contents