Advertisement

Introduction
Installation- Keyboard Wedge
1)
First of all, you must switch off power for the
terminal/computer.
2)
Disconnect the keyboard cable from the back of the
terminal/computer.
3)
Connect the appropriate interface cable to the scanner
and to the terminal/computer.
4)
Turn the terminal/computer power on.

RS-232

1)
Disconnect power to the terminal/computer.
2)
Connect the appropriate interface cable and external
power supply (DC adapter) to the scanner.
3)
Plug the serial connector into the serial port on the back
of your computer/terminal. Tighten the two screws to
secure the connector to the port.
4)
Plug the power pack into power source.
5)
Once the scanner has been fully connected, turn the
terminal/computer power back on.

USB

- USB (Simulate with RS-232)
1)
Connect the USB cable between scanner and PC.
2)
Windows will automatically detect the USB device.
3)
The driver setup appears. Insert the CD-ROM into your
PC.
4)
Install the USB driver. (Firmware must be version 3.00
or up. )
5)
Refer to Interface selection, set USB to Enable.
- USB (Simulate with Keyboard wedge)
1)
Connect the USB cable between scanner and PC.
2)
Windows will automatically detect the USB device.
Note: If any of the above operation is incorrect, turn off the
power immediately and checking any improper
connections. Go through all above steps again.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CD-3830 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for POSIFLEX CD-3830

  • Page 1 Introduction Installation- Keyboard Wedge First of all, you must switch off power for the terminal/computer. Disconnect the keyboard cable from the back of the terminal/computer. Connect the appropriate interface cable to the scanner and to the terminal/computer. Turn the terminal/computer power on. RS-232 Disconnect power to the terminal/computer.
  • Page 2 Default Setting for each barcode shown as below: Checksum Checksum Read Code Verification Transmission Code Type Enable Enable Enable UPC-A UPC-E EAN-13 EAN-8 Code-39 Interleaved 2 of 5 Industrial 2 of 5 Matrix 2 of 5 Codabar Code-128 Code-93 & V One digit Code-11 MSI/Plessey...
  • Page 3 Posiflex CD-3830 - 1D Barcode scanner Specification Model CD-3830 Operational Light Source 660 nm Visible Red LED Optical System 2048 pixel CCD (Charge-coupled device) Depth of Scan Field 0-250 mm (CODE 39, PCS=90%, 20mils) Scanning Width 120 mm Scan Speed...
  • Page 4 Weight 160 g (cable not included) Cable – K/B wedge Straight 2.0 m Cable – universal Straight 2.3 m type Connector type RJ-45 phone jack connector Case material ABS plastic Cushion material Rubber Electrical Input Voltage 5 VDC ± 0.25V Power –...
  • Page 5 Programming Manual (Reading special barcode) DOS Programming command through RS-232, Windows method configuration program Program upgrade Enabled by built-in flash memory Code type selection, check digit Programmable selection Decoding option Decoding characteristics option Transmitted character delay, Header selection, trailer selection, message suffix, good read beep tone and volume, scanner trigger selection Keyboard emulation type...
  • Page 6 Programming the Posiflex CD-3830 To program the CD-3830, you must scan a series of programming barcode in the correct order. Fold out the back cover of this manual. You will see a table of alphanumeric barcodes, which are used to program the various options presented.
  • Page 7 Program Barcode Program Option Bar Code Option Alphanumeric Entry Keyboard Wedge Interface RS-232 selection Wand emulation Keyboard/RS -232 Auto detection reserved Exit Option Barcode Back Fold Out Exit Barcode Finish barcode...
  • Page 8: Interface Selection

    Interface Selection This decoder build-in scanner comes in one model and supports interfaces such as keyboard wedge, RS232 serial wedge, wand emulation, and the latest USB interface. In most of the cases, simply selecting an appropriate cable with a device code will work for a specific interface. Interface selection: You can change factory interface default for other type interface.
  • Page 9: Keyboard Wedge

    Keyboard wedge As a keyboard interface, the scanner supports most of the popular PCs and IBM terminals. The installation of the wedge is a fairly simple process without any changes of software or hardware. Keyboard Type: Select keyboard type connector of your host computer.
  • Page 10 Keyboard wedge Keyboard Layout: The selecting of keyboard layout supports many country languages other than USA keyboard layout. First you need to confirm country language that you desire. In DOS, using command “keyb” to select the desirable keyboard layout or in WINDOWS entry “Control” then pops “Keyboard”...
  • Page 11 Program Option Bar Code Option Alphanumeric Entry Belgium Keyboard layout Danish France Germany Italian Portuguese Spanish Swedish Switzerland Latin American 00-08 0 : high clock rate Keyboard speed 8 : low clock rate Disable Enable Function key Alphabetic key Numeric keypad...
  • Page 12 Numeric key (Num lock state only) Alt+Keypad Keyboard wedge Exit Caps Lock: By selecting Caps Lock or No Caps Lock, scanner can get Caps Lock status. Power-on simulation: All of the PCs check the keyboard status during power-on selftest. It is recommended to Enable function if you are working without keyboard installation.
  • Page 13 Program Option Bar Code Option Alphanumeric Entry Caps lock”ON” Caps lock”OFF” Caps lock Disable Enable Power-on simulation 00-99 msec 00-99 Inter-character delay 00-99 10 msec 00-99 Block transmission delay Exit RS-232 CTS: Clear To Send (Hardware Signal) RTS: Request To Send (Hardware Signal)
  • Page 14 Xon: Transmit On (ASCII Code 11 Xoff: Transmit Off (ASCII Code13 Flow control: None-The communication only uses TxD and RxD signals without regard for any hardware or software handshaking protocol. RTS/CTS-If the scanner wants to send the barcode data to host computer, it will issue the RTS signal first, wait for the CTS signal from the host computer, and then perform the normal data communication.
  • Page 15 Option Bar Code Option Alphanumeric Entry None RTS/CTS Flow control Xon/Xoff ACK/NAK 00-99 (msec) 00-99 Inter-character delay 00-99 (10 msec) 00-99 Block transmission delay 00-99 (100 msec) 00-99 Response delay Exit Program...
  • Page 16: Wand Emulation

    Option Bar Code Option Alphanumeric Entry 300 BPS 600 BPS Baud rate 1200 BPS 2400 BPS 4800 BPS 9600 BPS 19200 BPS 38400 BPS None Parity Even 8 bits 7 bits Data bit One bit Two bits Stop bit Exit Wand Emulation Bar/space polarity: High/low- Black will be transmitted as a high voltage level...
  • Page 17 Low/high- Black will be transmitted as a low voltage level (0V) and space as high level (+5). Initial polarity: You must make sure what is Initial polarity of your wand decode device in stand-by (idle). So, initial signal state as a High voltage level (+5) or Low voltage level (0V). Program Option Bar Code Option...
  • Page 18 bar. Margin delay: It is a timer of zone like space zone of barcode label margin. The width of margin time will be added before and after in each barcode data automatically when it is transmitted. Transmit delay: It is a delay time between barcode data output.
  • Page 19 Reserved 00-99 (10 pixel) 00-99 Margin delay 00-99 (10 msec) 00-99 Transmit delay Exit Scan Scanning mode: Good-read off-The trigger button must be pressed to activate scanning. The light source of scanner stops scanning when there is a successful reading or no code is decoded after the Stand-by duration elapsed.
  • Page 20 Momentary-The trigger button acts as a switch. Press button to activate scanning and release button to stop scanning. Alternate-The trigger button acts as a toggle switch. Press button to activate or stop scanning. Timeout off-The trigger button must be pressed to activate scanning, and scanner stops scanning when no code is decoded after the Stand-by duration elapsed.
  • Page 21 Scanning mode Alternate Timeout off Continue 01-99 (second) 00-99 Stand-by duration 01-99 (10 msec) 01-99 Same barcode delay time 00-99 00-09 (00: no double Double confirm confirm) Exit Scan Multi field scan: The scanner can be read many sets of barcode data on the same scanning line at the same time, even if they are different kinds of barcode symbology.
  • Page 22 Maximum length setting, or otherwise the labels of the symbology will not be readable. In particular, you can set the same value for both Minimum and Maximum reading length to force the fixed length barcode decoded. The values of setting have no effect on certain symbologies with fixed length.
  • Page 23: Table Of Contents

    00-63 04-63 Global max.code length Disable Enable Inverted image scan Disable Enable CTS trigger Disable 30 second Position indication 60 second 90 second 120 second 150 second 180 second Continue Indication Exit Power on alert: After power-on the scanner it will generate an alert signal to indicate a successful self-test.
  • Page 24 Buzzer indication: After each successful reading, the scanner will beep buzzer to indicate a good barcode reading, and its Beep loudness, Beep tone freq. and Beep tone duration are adjustable. Beep loudness/ Beep tone freq./Beep tone duration: You can adjust Beep Loudness, Beep tone and Beep duration for a good reading upon favorite usage.
  • Page 25 Disable Enable Power on alert Disable Enable LED indication Disable Enable Buzzer indication 00-07 00-07 Beep loudness 00-99 (100Hz) 00-99 Beep tone freq. 00-99 (10 msec) 00-99 Beep tone duration UPCA Exit Read: Format Leading Data Digits Check Zero (11 Digits) Digit Check-sum transmission: By setting Enable, checks sum will be transmitted.
  • Page 26 Truncate leading/ending: The leading or ending digits of barcode data characters can be truncated when these values are set to non-zero. It will beep instead of reading anything when the truncate value is more than the barcode data digits or the value of Truncate Leading is overlapped with that of the Ending.
  • Page 27 Disable Enable Check-sum ransmission 00-64 00-64 Max.code length 00-64 00-64 Min.code length 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < A > Code ID setting 00-44 00-44 Insert group selection Exit UPCA...
  • Page 28 Supplement digits: The Supplement digits barcode is the supplemental 2 or 5 characters for WPC code. Format Supplement Digits Leading Data Digits Check 2 or 5 or Zero (11 Digits) Digit UCC / EAN Truncate Leading zero: The leading “0” digits of UPCA data characters can be truncated when the function is enabled.
  • Page 29 Read: Format Leading Data Digits (6 Check Zero Digits) Digits Check-sum verification: The checksum of EAN-13 is optional and made as the sum of the numerical value of the data digits. Check-sum transmission: By setting Enable, checks sum will be transmitted. Program Option Bar Code Option...
  • Page 30 UPCE Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Supplement digits: Format Supplement Digits Leading Data Digits Check 2 or 5 or Zero (6 Digits) Digit...
  • Page 31: Table Of Contents

    0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < E > Code ID setting 00-44 00-44 Insert group selection None 2 digits Supplement digits 5 digits UCC/EAN 128 Auto detection Disable Enable Truncate Leading zero Disable Enable Expansion Exit...
  • Page 32: Disable

    EAN-13 Read: Format Data Digits (12 Digits) Check Digits Check-sum verification: The checksum of EAN-13 is optional and made as the sum of the numerical value of the data digits. Check-sum transmission: By setting Enable, checks sum will be transmitted. Max./Min.
  • Page 33: Enable

    Read Disable Enable Check-sum verification Disable Enable Check-sum transmission 00-64 00-64 Max.code length 00-64 00-64 Min.code length 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending Exit...
  • Page 34: Digits

    EAN-13 Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Supplement digits: Format Supplement Digits Data Digits Check 2 or 5 or (12 Digits) Digits UCC / EAN ISBN/ISSN: The ISBN (International Standard Book Number) and ISSN (International Standard Serial Number) are two kinds of barcode for book and magazines.
  • Page 35: Ucc/Ean 128

    Insert group selection None 2 digits Supplement digits 5 digits UCC/EAN 128 Auto detection Disable Enable ISBN/ISSN conversion EAN-8 Exit Read: Format Data Digits Check (7 Digits) Digits Check-sum verification: The checksum of EAN-8 is optional and made as the sum of the numerical value of the data digits.
  • Page 36 Program Option Bar Code Option Alphanumeric Entry Disable Enable Read Disable Enable Check-sum verification Disable Enable Check-sum transmission 00-64 00-64 Max.code length 00-64 00-64 Min.code length 0-15 00-15 Truncate leading...
  • Page 37 0-15 00-15 Truncate ending Two characters 00-ffH, 00-ffH 00-ffH ASCII < FF > Code ID setting code 00-44 00-44 Insert group selection EAN-8 Exit Supplement digits: Format Supplement Digits Data Digits Check 2 or 5 or (7 Digits) Digits UCC/EAN 128 Truncate Leading zero: Refer to Truncate Leading zero of UPCE.
  • Page 38: Auto Detection

    Supplement digits 5 digits UCC/EAN 128 Auto detection Disable Enable Truncate Leading zero Disable Enable Expansion Exit Code 39 Read: Format Start Data Digits Checksum “★” ( Variable) (Optional) “★” Check-sum verification: The checksum of Code-39 is optional and made as the sum module 43 of the numerical value of the data digits.
  • Page 39 Disable Enable Read Disable Enable Check-sum verification Disable Enable Check-sum transmission Code 39 Exit Max./Min. code length: Each symbology has own Max./Min. Code Length. They can be set to qualify data entry. If their Max./Min. Code Length is zero, the Global Min./Max. Code Length is in effect.
  • Page 40 Insertion group selection: Refer to Insertion group selection of UPCA. Format: The Full ASCII Code-39 is an enhanced set of Code-39 that is the data with total of 128 characters to represent Full ASCII code. It is combined one of the digits +, %, $ and/ with one of the alpha digits (A to Z).
  • Page 41 Code ID setting 00-44 00-44 Insert group selection Standard Full ASCII Format Exit Code 39 Append: This function allows several symbols to be concatenates and be treat as one single data entry. The scanner will not transmit the embedded appending code (space for Code-39).
  • Page 42: Interleaved 2 Of 5

    Option Bar Code Option Alphanumeric Entry Disable Enable Append Disable Enable Start/end transmission Interleaved 2 of 5 Exit Read: Format Data Digits Checksum (Variable) (Optional) Check-sum verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Check-sum transmission: By setting Enable, checksum will be transmitted.
  • Page 43 Read Disable Enable Check-sum verification Disable Enable Check-sum transmission Interleaved 2 of 5 Exit Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.
  • Page 44 00-64 00-64 Max. code leading 00-64 00-64 Min. code leading 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < i > Code ID setting 00-44 00-44 Insert group selection Exit...
  • Page 45: Industrial 2 Of 5

    Industrial 2 of 5 Read: Format Data Digits Checksum (Variable) (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.
  • Page 46 Option Bar Code Option Alphanumeric Entry Disable Enable Read 00-64 00-64 Max. code length 00-64 00-64 Min. code length 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < i > Code ID setting 00-44 00-44 Insert group selection Exit...
  • Page 47 Matrix 2 of 5 Eur Read: Format Data Digits Checksum (Variable) (Optional) Checksum Verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min.
  • Page 48 Option Bar Code Option Alphanumeric Entry Disable Enable Read Disable Enable Checksum Verification Disable Enable Checksum Transmission 00-64 00-64 Max. code length 00-64 00-64 Min. code length 0-15 00-15 Truncate leading 0-15 00-15...
  • Page 49 Truncate ending 00-ffH ASCII 00-ffH code < B > Code ID setting 00-44 00- 44 Insert group selection Codabar Exit Read: Format Start Data Digits (Variable) Checksum (Optional) End Checksum Verification: The checksum is made as the sum module 16 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted.
  • Page 50 Option Bar Code Option Alphanumeric Entry Disable Enable Read Disable Enable Checksum Verification Disable Enable Checksum Transmission 00-64 00-64 Max. code length 00-64 00-64 Min. code length 0-15 00-15 Truncate leading 0-15 00-15...
  • Page 51 Truncate ending 00-ffH ASCII 00-ffH code < % > Code ID setting Exit Codabar Insertion group selection: Refer to Insertion group selection of UPCA. Start/End type: The Codabar has four pairs of Start/End pattern; you may select one pair to match your application. Start/End Transmission: Refer to Start/End Transmission of Code 39.
  • Page 52 ABCD/ABCD abcd/abcd Start/End type ABCD/TN*E Abcd/tn*e Disable Enable Start/End transmission Code-128 Exit Read: Format Data Digits Checksum (Variable) (Optional) Checksum Verification: The checksum is made as the sum module 103 of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted.
  • Page 53: Second

    Disable Enable Checksum Verification Disable Enable Checksum Transmission Code-128 Exit Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.
  • Page 54 Option Bar Code Option Alphanumeric Entry 00-64 00-64 Max. code length 00-64 00-64 Min. code length 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < # > Code ID setting 00-44 00-44 Insert group selection Standard UCC/EAN-128 Format...
  • Page 55 Disable Enable Append 00-ffH ASCII 00-ffH code < # > UCC/EAN-128 ID setting...
  • Page 56 00-ffH ASCII 00-ffH code Field separator code Exit Code-93 Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The checksum is made as the sum module 47 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will transmitted.
  • Page 57 Read Disable Enable (two Checksum digits) Verification Disable Enable Checksum Transmission 00-64 00-64 Max. code length 00-64 00-64 Min. code length 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < & > Code ID setting...
  • Page 58 00-44 00-44 Insert group selection Exit Code-11 Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The checksum is presented as the sum module 11 of all data digits. Checksum Transmission: By setting Enable, checksum1 and checksum2 will be transmitted upon your selected checksum verification method.
  • Page 59 Disable Enable Read Disable One digit Checksum Two digits Verification Disable Enable Checksum Transmission 00-64 00-64 Max. code length 00-64 00-64 Min. code length 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < O >...
  • Page 60 Code ID setting 00-44 00-44 Insert group selection Exit MSI/plessey Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The MSI/Plessey has one or two optional checksum digits. The checksum is presented 3 kinds of method Mod10, Mod10/10 and Mod 11/10. The checksum1 and checksum2 will be calculated as the sum module 10 or 11 of the data digits.
  • Page 61 Option Bar Code Option Alphanumeric Entry Disable Enable Read Disable Mod 10 Checksum Mod 10/10 Verification Mod 11/10 Disable Enable Checksum Transmission 00-64 00-64 Max. code length 00-64 00-64 Min. code length 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending...
  • Page 62 00-ffH ASCII 00-ffH code < @ > Code ID setting 00-44 00-44 Insert group selection Exit UK/plessey Read: Format Data Digits Checksum1+2 (Variable) (Optional) Checksum Verification: The UK/Plessey has one or two optional checksum digits. The checksum1 and checksum2 will be calculated as the sum module 10 or 11 of the data digits.
  • Page 63 Option Bar Code Option Alphanumeric Entry Disable Enable Read Disable Enable Checksum Verification Disable Enable Checksum Transmission 00-64 00-64 Max. code length 00-64 00-64 Min. code length 0-15 00-15 Truncate leading 0-15 00-15...
  • Page 64 Truncate ending 00-ffH ASCII 00-ffH code < @ > Code ID setting 00-44 00-44 Insert group selection Exit Telepen Read: IATA (International Air Transport Association). Checksum Verification: The checksum is presented as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum will be transmitted.
  • Page 65 Entry Disable Enable Read Disable Enable Checksum Verification Disable Enable Checksum Transmission 00-64 00-64 Max. code length 00-64 00-64 Min. code length 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending...
  • Page 66: Standard 2 Of

    00-ffH ASCII 00-ffH code < S > Code ID setting 00-44 00-44 Insert group selection Numeric only Full ASCII only Format Exit Standard 2 of 5 Read: Format Data Digits Checksum1 (Variable) (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39.
  • Page 67 Option Bar Code Option Alphanumeric Entry Disable Enable Read 00-64 00-64 Max. code length 00-64 00-64 Min. code length 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < i > Code ID setting 00-44 00-44 Insert group...
  • Page 68 selection Exit RSS-14 Read: Format Data Digits Checksum1 (Variable) (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.
  • Page 69 00-64 00-64 Min. code length 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < R4 > Code ID setting 00-44 00-44 Insert group selection Disable Enable UCC/EAN128 emulation RSS-Limited Exit Read: Format Data Digits Checksum1...
  • Page 70 (Variable) (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. UCC/EAN 128 emulation: Refer to UCC/EAN 128 emulation of RSS-14.
  • Page 71 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < RL > Code ID setting 00-44 00-44 Insert group selection Disable Enable UCC/EAN128 emulation Exit RSS-Expanded Read: Format Data Digits Checksum1 (Variable) (Optional)
  • Page 72 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. UCC/EAN 128 emulation: Refer to UCC/EAN 128 emulation of RSS-14.
  • Page 73: China Post

    0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < RX > Code ID setting 00-44 00-44 Insert group selection Disable Enable UCC/EAN128 emulation Exit China Post Read: Format Data Digits Checksum1 (Variable) (Optional)
  • Page 74 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Program Option Bar Code Option Alphanumeric Entry...
  • Page 75: Italian Pharmacode

    0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < t > Code ID setting 00-44 01-44 Insert group selection Exit Italian Pharmacode Read: Format Data Digits Checksum1...
  • Page 76 (Variable) (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Leading “A”: If this function is enabled, each prefix of data shall be A.
  • Page 77 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 01-ffH code < p > Code ID setting 00-44 00-44 Insert group selection Disable Enable Leading “A” Exit String setting Prefix characters: Up to 22 ASCII characters may be sent before data digits.
  • Page 78: None

    after data digits. Preamble/ Postamble characters: They are appended to the data automatically when each barcode is decoded. Example: Add a prefix/suffix or preamble/postamble for all symbologies. In this example, you are sending a $ symbol as a prefix for all symbologies.
  • Page 79 None 1-22 characters 00-ffH ASCII Postamble code characters setting None 1-22 characters 00-ffH ASCII Insert G1 characters code setting None 1-22 characters 00-ffH ASCII Insert G2 characters code setting None 1-22 characters 00-ffH ASCII Insert G3 characters code setting None 1-22 characters 00-ffH ASCII Insert G4 characters...
  • Page 80 Steps: 1) Scan Programming and Insert G1 characters setting barcode. 2) Use the ASCII code table to find the value of A→41,B→ 3) Scan 4, 1 and 4, 2 from the barcode on the fold out back page. 4) Scan Finish from the barcode on the fold out page. 5) Repeat the same procedure in Insert G2 characters setting.
  • Page 81 None 1-22 characters 00-ffH ASCII Insert G4 characters code setting Exit Transmission Preamble transmission: By setting Enable, Preamble will be appended before the data transmitted. Postamble transmission: By setting Enable, Postamble will...
  • Page 82 be appended after the data is transmitted. Insert data group 1-4 position: The scanner offers 4 positions to insert among the symbol. The position default value is “00” to indicate no character insertion. Beside, make sure insertion positions are not greater than the symbols; otherwise the insertion data is not effective.
  • Page 83 00-64 00-64 (00: no insertion) Insert data group 2 position 00-64 00-64 (00: no insertion) Insert data group 3 position 00-64 00-64 (00: no insertion) Insert data group 4 position Before code data After code data Code ID position Exit Transmission Code ID transmission: If your application is needed to transmit Code ID, you must set this to Proprietary ID or AIM...
  • Page 84 Code length transmission: A number of data digits can be transmitted before the code data when Enable is selected. The total length of the barcode is the number of barcode data except Truncate Leading/Ending Digits. And the length is a number with two digits.
  • Page 85: Test Chart

    Disable Enable Code name transmission Disable Upper case Case conversion Lower case *For barcode data only Exit Format of barcode data transmission: Code Barcode Prefix Name Preamble Postamble Suffix Length data Insert groups Test Chart...
  • Page 86 CODABAR-PARA CODE-11 PARA CODE-128 PARA CODE-39 PARA CODE-93 PARA EAN-13 PARA...
  • Page 87 STANDRAD-25 PARA EAN-8 PARA INDUSTRIAL-25 PARA UPCE PARA INTERLEAVED-25 PARA...
  • Page 88 MATRIX 25 PARA MSI/PLESSEY PARA UPCA PARA UK/PLESSEY PARA...
  • Page 89 ASCII Code Table Note: For keyboard wedge only. Null Down Left Right PgUp PgDn Home Enter Insert Ctrl+ Delete Alt+...
  • Page 90 ﹜ > ∼ Parameter Setting List Program Barcode standard parameter setting list If you wish to display the current configuration of your CD-3830, scanner over the host terminal/computer, scan the Barcode standard parameter setting list bar code. Unique parameter list...
  • Page 91 Firmware version list If you wish to display the firmware version, scan the Firmware version list. WARNING: Default value initialization If you wish to return the CD-3830 to all the factory default settings, scan the Default value initialization bar code. Exit...

Table of Contents