5.3. Peripherals Control
The reader's peripherals control commands are implemented by using SCardControl with Control
Code SCARD_CTL_CODE(3500).
5.3.1.
Get Firmware Version
This command is used to get the reader's firmware message.
Get Firmware Version Format (5 bytes)
Command
Get Firmware Version
Get Firmware Version Response Format (5 bytes + Firmware Message Length)
Response
Result
Example:
Response = E1 00 00 00 0F 41 43 52 31 32 35 32 55 5F 56 32 30 32 2E 32
Firmware Version (HEX) = 41 43 52 31 32 35 32 55 5F 56 32 30 32 2E 32
Firmware Version (ASCII) = "ACR1252U_V202.2"
ACM1252U-Y3 – Reference Manual
Version 1.03
Class
E0h
Class
INS
P1
P2
E1h
00h
00h
00h
INS
P1
P2
00h
00h
18h
Le
Number of bytes to receive
Lc
00h
Data Out
Firmware Version