ACS ACM1252U-Y3 Reference Manual page 62

Usb nfc reader module
Table of Contents

Advertisement

5.4.1.1.
Set Initiator Mode Timeout
This command is used to set the timeout for Initiator Mode.
Set Initiator Mode Timeout Command Format (7 bytes)
Command
Set Initiator Mode
Note: Unit = 10 ms, default value of Initiator Mode Timeout = 00 64h (100 * 10 ms = 1000 ms).
Set Initiator Mode Timeout Response Format (7 bytes)
Response
Result
Where:
Timeout
ACM1252U-Y3 – Reference Manual
Version 1.03
Class
INS
E0h
00h
Class
INS
P1
E1h
00h
00h
2 bytes. Timeout for Initiator Mode (unit = 10 ms).
P1
P2
Lc
00h
41h
02h
P2
Le
Data Out
Timeout
00h
02h
(MSB)
Data In
Timeout
Timeout
(MSB)
(LSB)
Timeout
(LSB)