ACS ACM1252U-Y3 Reference Manual page 24

Usb nfc reader module
Table of Contents

Advertisement

Error Status
XX 6A 80h
XX 64 00h
XX 64 01h
XX 6F 00h
The first value byte indicates the number of the erroneous data object XX, while the last two bytes
indicate the explanation of the error. SW1 SW2 values based on ISO 7816 are allowed.
If there are more than one data objects in the C-APDU field and one data object failed, IFD can
process the following data objects if they do not depend on the failed data object.
5.2.3.2.
Manage Session Command
This command is used to manage the transparent session. This includes starting and ending a
transparent session. Through this command, you can also manage the operation environment and the
capabilities of the IFD within the transparent session.
Manage Session Command
Command
Manage Session
Where:
Data Object (1 byte)
Tag
80h
81h
82h
83h
84h
5F 46h
FF 6Dh
FF 6Eh
Manage Session Response Data Object
Tag
Data Object
C0h
Generic Error status
80h
Version data object
FF 6Dh
IFD parameter data object
ACM1252U-Y3 – Reference Manual
Version 1.03
Description
Data object XX with unexpected vale
Data Object XX execution error (no response from IFD)
Data Object XX execution error (no response from ICC)
Data object XX failed, no precise diagnosis
Class
INS
FFh
C2h
Data Object
Version Data Object
Start Transparent Session
End Transparent Session
Turn Off RF Field
Turn On RF Field
Timer
Get Parameter
Set Parameter
P1
P2
00h
00h
DataLen
Lc
Data In
DataObject
(N bytes)
Page 24 of 92
www.acs.com
info@acs.com.hk
.hk
www.acs.com.hk

Advertisement

Table of Contents
loading

Table of Contents