Specifications; Obtaining Service; Contact Information - CardioQuip MCH-1000 Operators & Service Manual

Cardiopulmonary bypass temperature controller
Hide thumbs Also See for MCH-1000:
Table of Contents

Advertisement

CardioQuip Modular Cooler-Heater Operator/Service Manual

Specifications

Dimensions (LxWxH)
Weight (empty/full/max)
Water capacity
Water Connections
Maximum flow rate (high/low)
Maximum pressure
Electrical
Temperature control (℃)
Alarm sound pressure range (dB) 41 - 58
3
Induced airflow (ft
/min)
Operating environment
Power consumption (W)
Ground resistance (Ω)
Leakage current (µA)
EMC compliance

Obtaining Service

Contact CardioQuip with questions on parts, servicing or returning merchandise. Please make
sure the unit's model and serial number are available prior to contacting service personnel. If you
are experiencing problems with your unit, the service representative will assist you in corrective
procedures or in returning the merchandise. Upon request, CardioQuip will make available
circuit diagrams, component part lists, descriptions, calibration instructions, or other information
which will assist appropriately qualified technical personnel to troubleshoot or repair parts of the
equipment that CardioQuip determines to be field repairable. Replacement of internal electrical
components should be performed only by CardioQuip service personnel.

Contact Information

CardioQuip, LP
3827 Old College Road • Bryan, Texas 77801
USA
MCH-1000(i): 26x16x35 in (66x42x89 cm)
MCH-1000(m): 19x9x16 in (48x23x42 cm)
MCH-1000(i): 85 lbs (39 kg) / 165 lbs (75 kg) / 258 lbs (117 kg)
MCH-1000(m): 45 lbs (21 kg) / 65 lbs (30 kg) / 76 lbs (34 kg)
MCH-1000(i): Min 3 gal. (12 L), Max 9 gal. (36 L)
MCH-1000(m): Min 1 gal. (3.8 L), Max 2.5 gal. (9.5 L)
Quick-connect, no-spill two-way shutoff fittings.
Tank drain accepts standard garden hose (GHT) fitting.
20 / 14 LPM (5.3 / 3.7 GPM)
83 kPa / 12 psi (closed loop, blocked flow)
115VAC / 60Hz, 16A (Class 1 equipment per UL 544)
230VAC / 50Hz, 9A (Class 1, Type BF equipment per UL 2601-1)
Range 0.0 - 42.0, Accuracy ±0.5, Setting 0.1
<50 (base) / <100 (TEC Module) / < 300 (Refrigeration Module)
5 - 40℃, 0 - 90% humidity
Max Peak 1900, Typ < 1740
Max 0.1
< 100
CISPR 11:2009+A1:2010, IEC 61000-3-2:2005/A1:2008/A2:2009,
IEC 61000-3-3:2013, IEC 60601-1-2:2014
Tel: 888-267-6700 • Fax: 979-691-0206
Email:
Internet:
service@cardioquip.com
www.cardioquip.com
Page 7