Oracle MICROS 6 Series Setup Manual page 19

Hide thumbs Also See for MICROS 6 Series:
Table of Contents

Advertisement

Table 4-1
Starting State
Unplugged
NOPOWER
NOPOWER
NOPOWER
NOPOWER
ON
ON
ON
ON
*Based on the default BIOS power settings.
Power Considerations for Peripheral Devices
The following table specifies the I/O port or connectors, their related power bus, and
the power consumed by the port, depending on BIOS or Diagnostics Utility
configurations. Use the table when considering peripherals.
Table 4-2
Port or Connector
12V Power Output
12V Power USB Header
Series 2 Cash Drawer
USB 2.0
Customer Display
High Speed USB
24V Power USB
RJ-45 Powered Serial
Micro USB
Power Management State Changes
Event
AC power is connected to a wall outlet and the
last recorded power state was not the ON state.
The operator presses the power button for less
than 1 second.
The operator presses the power button for
more than 4 seconds.
A server application sends a Wake On LAN
command.
AC power fails and then is restored.
The operator presses the power button for
more than 4 seconds.
The application shuts down the workstation.
The Client Application Loader sends a Restart
command.
AC power fails and then is restored.
Port Power Specifications
Power Considerations for Peripheral Devices
Resulting State
NOPOWER
ON
ON
ON
NOPOWER*
NOPOWER
NOPOWER
NOPOWER and then ON
ON
Available Power Capability
+12V @ 2.5A (30W)
+12V @ 1.5A (18W)
Can be configured as +24V or +12V, with a
shared 1A rating
+5V @ 0.5A (2.5W)
+5V @ 1.5A (7.5W)
+5V @ 0.9A (4.5W)
+24V @ 3.5A (84W)
Can be configured as:
+5V @ 1.0A (5W)
+9V @ 1.0A (9W)
+12V @ 1.0A (12W)
+5V @ 0.5A (2.5W)
Chapter 4
4-2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Micros 620Micros 650Micros 610

Table of Contents