Wiznet WizFi360 At Instruction Set page 13

Hide thumbs Also See for WizFi360:
Table of Contents

Advertisement

<databits>: data bit parameter
- 5: 5-bit data
- 6: 6-bit data
- 7: 7-bit data
- 8: 8-bit data (factory default)
<stopbits>: Stop Bit Parameter
- 1: 1 bit stop bit (factory default)
- 2: 2 bit stop bit
<parity>: parity parameter
- 0: None (factory default)
- 1: Odd
- 2: Even
<flow control>: flow control parameter
- 0: Off flow control (factory default)
- 1: ON RTS / CTS hardware flow control
Return Values
\r\n
and
OK\r\n
descriptions
Command: AT+UART_DEF=115200,8,1,0,0\r\n
Examples
Reply:\r\n
OK\r\n
Command string
AT+UART_DEF?
Return Value:
Return Values
+UART_DEF:<baudrate>,<databits>,<stopbits>,<parity>,<flow control>\r\n
and
OK\r\n
descriptions
Description: Parameter above
Command: AT+UART_DEF?\r\n
Examples
Reply: +UART_DEF:115200,8,1,0,0\r\n
OK\r\n
Command Description: This setting will be saved to Flash, after the next reboot / power still valid.
NOTE: If using WizFi360 hardware flow control, the user needs to access the flow control device of pin WizFi360, refer to the specific
connection WizFi360 User Manual.
WizFi360 AT command
Function Description
Query the baudrate