Trueblend Sb-4 Batch Hopper Calibration; Tr U E B L E N D S B - 4 B A T C H H O P P E R C A L I B R A T I O N - Conair TrueBlend SB-4 User Manual

Table of Contents

Advertisement

Tr u e B l e n d S B - 4 B a t c h H o p p e r
C a l i b r a t i o n
1
Turn power on to the blender. Once the controller display comes on and the blender
overview screen is displayed, continue with the calibration.
2
Press the Setup button on the touch screen. The TrueBlend SB-4 setup screen will
appear.
3
Press the Batch Hopper button, located at the right side of the screen. The next screen
to appear will be the Set up screen for the batch hopper.
4
Press the Calibrate button on the left side of the screen.
5
Press the Manual Calibrate button. It is a good idea to re-calibrate the unit after it has
been transported and mounted. Re-calibrating the unit assures that the start weight on the
scale inside the blender is zero.
Tip: The weigh bin must be in place, and empty, when you perform this task. If the bin is not in place,
the calibration will be inaccurate and will need to be redone.
6
Press the 'OK' button to obtain the Zero Weight Calibration Factor. Please stand by,
while the system obtains the Zero Weight Calibration Factor.
7
Enter the Test Weight Value, then press 'OK'.
NOTE: The test weight value should not exceed the maximum capacity of the weighing system.
Blender Model
TB45
TB100
TB250
TB500
TB900
TB1800
TB2500
TB3500
8
Place the test weight into the hopper and press 'OK' to continue with the calibration.
Stand by while the system obtains the Test Weight AD Value.
9
Stand by while the system obtains the Test Weight AD Value.
10
Remove the test weight from the hopper.
11
Press the Home button to return to the Home screen.
Test Weight Grams
1 kg
1 kg
5 kg
5 kg
10 kg
10 kg
10 kg
10 kg
Test Weight Part Number
26702901
26702901
26702902
26702902
26702903
26702903
26702903
26702903
I n s t a l l a t i o n l
3 - 9