L o a d i n g E q u i p m e n t

The TrueBlend SB-4 component hoppers are generally loaded with a vacuum receiver. The
proper operation of the loading receiver component is necessary for accurate control of the
TrueBlend SB-4 component hopper.

S o f t w a r e U p g r a d e s

Upgrading software on the TrueBlend SB-4 controller is accomplished by downloading the
latest software version from Conair, burning the software onto a USB stick, and rebooting
the TrueBlend SB-4 touch screen controller.
To download the most up to date TrueBlend SB-4 software version, contact Conair service.
S h u t t i n g O f f i n a n E m e r g e n c y
1
Switch the main switch to off. The power supply is interrupted. If the cone valve was
open, it is closed. All other machine movement is stopped immediately. The batch is
not finished. The main switch can also be locked manually with a lock.
R e s t a r t i n g a f t e r E m e r g e n c y S t o p
1
Switch the main switch to on. If switching on within two minutes of stop, the unit con-
tinues the interrupted process. This function is used to keep downtime in the event of a
short power interruption as short as possible. The screen that was last open before
switching off or power failure is opened. If switching on after more than two minutes,
the internal functions are completely reset. The start screen will appear.
2
Remove the weigh bin carefully to prevent damage to the load cell and empty it. (Only
necessary if the metering cycle was interrupted.)
Contact Conair Parts
1 800 458 1960
From outside of the United
States, call:
814 437 6861
M a i n t e n a n c e l
5 - 3