C a l i b r a t i n g / A d j u s t i n g t h e S e n s o r

The level sensor switched when material passes in front of the active area. The level sensor
adjustment depends on the type of material and must be adjusted accordingly.
Calibrating with no material present
1
Make sure the Efector sensor is installed into the rear of the blender chassis so
that it is flush with the inside of the rear of the mixing chamber. It should be
installed as close as possible to being flush and still allow access to push button and
indicator light (should be facing away from mixing motor - towards the outside of
the unit).
2
Make sure the supplied nut is installed in the back of the sensor, tightened against
the weld coupling on the back of the chassis.
3
Turn power on, and make sure that all mixing components are in place, and close
the door.
4
Use a small screwdriver or pen to press the OUT OFF adjustment pushbutton
until the yellow LED ring flashes at a rate of 1Hz. This should take about 2 seconds.
Release the OUT OFF button and the yellow LED ring will turn off. The sensor is now
set for emptying mixing chamber and should need no further adjustment.
IMPORTANT - Do not adjust the OUT ON LED, this will switch the operation of the
level sensor.
Sensing face
Threaded sleeve
(Continued)