Changing Material In A Blender Component; C H A N G I N G M A T E R I A L I N A B L E N D E R C O M P O N E N T - Conair TrueBlend SB-4 User Manual

Table of Contents

Advertisement

C h a n g i n g M a t e r i a l i n a B l e n d e r
C o m p o n e n t
( c o n t i n u e d )
Manual Cleaning
1
Turn off the main power and use the disconnect on the power cabinet.
2
Disconnect compressed air.
3
Open the front access door and remove the weigh bin.
4
Position a deflector (cardboard tray) to divert material from collecting in the mix
chamber to and outside drum or bucket.
Tip: A Conair Drain Chute Accessory is available. This allows the discharge valves to be operated in
manual mode.
5
Using a "dowel rod" approximately 12 inches long, press vertically into the respec-
tive valve opening and raise the plunger cone to allow materials to flow from the
material compartments. Material will flow out of the hopper compartment through the
valve opening onto the deflector and into the drum or bucket.
6
Discharge the material completely and clean the material hopper from the top
down.
Tip: You may also want to clean the material receiver at this time while accessing the gravity dump
valve through the respective blender clean out door.
7
Reassemble blender. If using the optional drain chute, be sure to engage the safety
switch into the compartment receptacle.
Shown with the
optional drain
chute and safety
interlock.
Contact Conair Parts
1 800 458 1960
From outside of the
United States, call:
814 437 6861
M a i n t e n a n c e l